A

Configure and Environment Commands

Table A-1. ENV Command Parameters (Continued)

ENV Parameter and Options

Default

Meaning of Default

 

 

 

 

 

 

Auto Boot at power-up only [Y/N]

Y

Auto Boot is attempted

 

 

at power-up reset only.

Auto Boot Controller LUN

00

LUN of a disk/tape

 

 

controller module

 

 

currently supported by

 

 

the Bug. The default is

 

 

$0.

Auto Boot Device LUN

00

LUN of a disk/tape

 

 

device currently

 

 

supported by the Bug.

 

 

The default is $0.

Auto Boot Abort Delay

15

This is the time in

 

 

seconds that the Auto

 

 

Boot sequence will

 

 

delay before starting the

 

 

boot. The purpose of the

 

 

delay is to allow the

 

 

user the option of

 

 

stopping the boot by use

 

 

of the Break key. The

 

 

time value is from 0

 

 

through 255 seconds.

Auto Boot Default String [NULL for an empty

<none>

The user may specify a

string]

 

string (filename) which

 

 

is passed on to the code

 

 

being booted. The

 

 

maximum length of the

 

 

string is 16 characters.

 

 

The default is the null

 

 

string.

ROM Boot Enable [Y/N]

N

The ROMboot function

 

 

is disabled.

ROM Boot at power-up only [Y/N]

Y

ROMboot is attempted

 

 

at power-up only.

ROM Boot Enable Search of VMEbus [Y/N]

N

VMEbus address space

 

 

will not be accessed by

 

 

ROMboot.

 

 

 

A-4