Moxa Technologies C168P user manual RS-232 Cable Wiring for Opt8A/B/C/D/S

Models: C168P

1 80
Download 80 pages 46.89 Kb
Page 57
Image 57
Connection Option (Opt8x) and Cable Wiring

5

Connection Option (Opt8x) and Cable Wiring

In serial data communications, the term DTE is for Data Terminal Equipment like PC COM1/2, serial printer and terminal. The term DCE is for Data Communication Equipment like modem.

RS-232 Cable Wiring for Opt8A/B/C/D/S

RS-232 8-port connection boxes/octopus cable designed for C168P are:

Opt8A: 8-port RS-232 DB25 female connection box

Opt8B: 8-port RS-232 DB25 male connection box

Opt8C: Octopus cable with 8 male RS-232 DB25 ports

Opt8D: Octopus cable with 8 male RS-232 DB9 ports

Opt8S: 8-port RS-232 DB25 surge protected female connection box

C168P User’s Manual 5-1

Page 57
Image 57
Moxa Technologies C168P user manual RS-232 Cable Wiring for Opt8A/B/C/D/S, Connection Option Opt8x and Cable Wiring