Opt8A/S

Type 3: To connect C168P to a DTE with 3-pin wiring.

If the “Hardware flow control” feature is set to “ON”, you must loop back (or short) the RTS with CTS and DSR with DTR, DCD on MOXA site, indicated in dash-lines of the following diagrams. If the “Hardware flow control” feature is set to “OFF”, you could just leave RTS, CTS, DSR, DTR, DCD open, ignoring the connection indicated in dash-lines.

Opt8A/S

PC COM2 port, Serial Printer, Terminal, or any DTE Device

Opt8A/S

 

 

 

DTE Device

DB25 Female

 

 

 

DB25 Male

RxD

2

 

2

TxD

 

TxD

3

 

3

RxD

 

GND

7

 

7

GND

 

RTS

5

4

RTS

CTS

4

5

CTS

DTR

20

6

DTR

DST

6

20

DSR

DCD

8

8

DCD

Opt8B/C

PC COM2 port, Serial Printer, Terminal, or any DTE Device

Opt8B/C

 

 

 

DTE Device

DB25 Male

 

 

 

DB25 Male

TxD

2

2

TxD

RxD

3

3

RxD

GND

7

 

7

GND

 

RTS

4

4

RTS

CTS

5

5

CTS

DSR

6

6

DTR

DTR

20

20

DSR

DCD

8

8

DCD

5-6C168P User’s Manual

Page 62
Image 62
Moxa Technologies user manual 5-6 C168P User’s Manual, Opt8A/S, DTE Device