There are 2 solutions to control RS-485 2-wire transmission.

Serial Programming Tools

There are 2 solutions to control RS-485 2-wire transmission.

Solution 1

The following model is common in RS-485 2-wire transmission.

sio_SetWriteTimeouts(port, 0); /* Set sio_write() into block mode if

 

for Windows NT and Windows 95/98 */

sio_RTS(port, 1);

/* Turn on RTS signal. The RS-485

 

port is ready for transmitting data. */

sio_write(port, buff, 10);

/* Write 10 byte characters in "buff".

 

The function blocks until last

 

character transmitted */

sio_RTS(port, 0);

/* Turn off RTS signal. The RS-485

 

port is ready for receiving data. */

sio_read(port, buff, 10);

/* Read 10 bytes */

Solution 2

function in PComm or API-232 library. It

There is a dedicated RS-485

integrates the above functions of solution 1 regarding sending data as one.

sio_putb_x(port, buff, tick ); /*

1.

Turn on RTS and ready for

 

 

transmitting data.

 

2.

Send data.

 

3.

Wait for tick time.

 

4.

Turn off RTS and ready for

 

 

receiving data. */

For more information on these functions, please refer to PComm library on-line Help file for Windows NT and Windows 95/98 or API-232.txt file for DOS, respectively

C168P User’s Manual 4-9