Appendix B

Degraded RAID Array

A RAID 1, RAID 5 or RAID 10 volume is reported as degraded when one of its hard drive members fails or is temporarily disconnected, and data mirroring is lost. As a result, the system can only utilize the remaining functional hard drive member. To re-establish data mirroring and restore data redundancy, refer to the procedure below that corresponds to the current situation.

Missing Hard Drive Member

1.Make sure the system is powered off.

2.Reconnect the hard drive.

3.Reboot the system to Windows; the rebuild will occur automatically. Failed Hard Drive Member

1.Make sure the system is powered off.

2.Replace the failed hard drive with a new one that is of equal or greater capacity.

3.Reboot the system to Intel RAID Option ROM by press <Ctrl> and <I> keys simultaneously during the Power-On Self Test (POST).

RAID Volumes

 

 

 

 

 

 

ID

Name

Level

Strip

Size

Status

Bootable

0

Volume0

RAID 1(Mirror) N/A

XXX.XGB Degraded

Yes

Physical Disks:

 

 

 

 

 

 

Port

Device Model

Serial #

 

Size

Type/Status(Vol ID)

1

XXXXXXXXXXXXX

XXXXXXXXXXXXX

XXX.XGB

Member Disk (0)

2

XXXXXXXXXXXXX

XXXXXXXXXXXXX

XXX.XGB

Member Disk (0)

Press

<CTRL-I>

to enter Configuration Utility..

 

 

 

 

 

 

 

 

 

 

 

 

4. Select the port of the destination disk for rebuilding, and then press ENTER.

 

 

 

 

 

 

 

 

 

 

 

 

[ MAIN MENU ]

 

 

 

 

1.

Create RAID Volume

4.

Recovery Volume Options

 

2.

 

 

[ DEGRADED VOLUME DETECTED

]

 

 

Delete RAID Volume

4.

Recovery Volume Options

 

 

“Degraded” volume and disk available for rebuilding detected. Selecting

 

 

 

 

5.

Exit

operating system.

 

 

a disk initiates a rebuild. Rebuild completes in the

 

 

 

 

[ DISK / VOLUME INFORMATION

]

 

RAID Volumes :

 

 

 

 

 

 

None

defined.Select the port of the destination disk for rebuilding (ESC to exit):

 

 

Port

Drive

Model

Serial #

 

 

Size

Physical

1

XXXX-XXXXXXXX

XXXXXXXXXXXXXX

XXX.XGB

Devices :

 

 

 

 

 

Port

Device Model

Serial #

 

 

Size

Type/Status (Vol ID)

1

XXXX-XXXXXXXX

XXXXXXXXXXXXXX

XXX.XGB

Non-RAID Disk

2

 

 

[ ↑↓] - Previous/ Next

[ENTER] - Select

[ESC] - Exit

XXXX-XXXXXXXX

XXXXXXXXXXXXXX

XXX.XGB

Non-RAID Disk

 

 

 

 

 

 

 

 

 

[ ↑↓] - Select

[ESC] - Exit

[ENTER] - Select Menu

Intel RAID

B-10

Page 112
Image 112
MSI Z87-MPOWER-MAX manual Degraded RAID Array, Main Menu