DCA-70SSJU SERIES — GENERATOR SHUT-DOWN PROCEDURE

Shutdown Procedure - Ignition Switch (Up to S/N 73002140)

To shutdown the generator use the following procedure:

1.Place both the MAIN, GFCI and LOAD circuit breakers as shown in Figure 45 to the "OFF“ position.

2.Place the engine throttle control in the “LOW” position (Figure 71).

Shutdown Procedure - Engine Controller (S/N 73002141~)

To shutdown the generator use the following procedure:

1.Place both the MAIN, GFCI and LOAD circuit breakers as shown in Figure 45 to the "OFF“ position.

2.Place the engine speed switch in the “LOW” position (Figure 73).

Figure 71. Engine Throttle Control (Low)

3.Let the engine cool by running it for 3-5 minutes with no load applied.

4.Turn the Ignition Key Switch (Figure 72) to the “OFF“ position.

Figure 73. Engine Speed Switch (Low)

3.Let the engine cool by running it for 3-5 minutes with no load applied.

4.Place the Auto-Off/Reset-Manual switch (Figure 74) to the “OFF/Reset“ position.

Figure 72. Engine Ignition Switch (Stop)

Figure 74. Off/Manual Auto Switch (Off)

 

5. Remove all loads from the generator.

Emergency Shutdown Procedure - Ignition Switch (Up to S/N 73002140)

1.To shut-down the engine in the event of an emergency, switch the MAIN, GFCI and LOAD (Figure 61) circuit breakers to “OFF” position.

2.Turn the ignition switch key to the “STOP” position (Figure 72).

5.Verify that the all status LED on the MPEC display (Figure 68) are "OFF" (not lit).

6.Remove all loads from the generator.

Emergency Shutdown Procedure - Engine Controller (S/N 73002141~)

1.To shut-down the engine in the event of an emergency, switch the MAIN, GFCI and LOAD (Figure 45) circuit breakers to “OFF” position.

2.Place the Auto-Off/Reset-Manual switch (Figure 74) to the “OFF/Reset“ position.

CAUTION:

NEVER stop the engine suddenly except in an emergency. DO NOT use the emergency stop switch a as method of shutting down the generator.This switch is ONLY to be used in the event of an emergency.

PAGE 46 — DCA-70SSJU SERIES — OPERATION AND PARTS MANUAL (STD) — REV. #5 (06/03/03)

Page 46
Image 46
Multiquip operation manual DCA-70SSJU Series Generator SHUT-DOWN Procedure, Shutdown Procedure Ignition Switch Up to S/N