DCA-70SSJU SERIES — GENERATOR OUTPUTS

Generator OutputVoltages

A wide range of voltages are available to supply voltage for many different applications. Voltages are selected by using the voltage selector switch (Figure 15). To obtain some of the voltages as listed in Table 6 (see below) will require a fine adjustment using the voltage regulator (VR) control knob located on the control panel.

Voltage Selector Switch

The voltage selector switch (Figure 15) is located above the UVWO Hard Wire Hook-up Panel. It has been provided for ease of voltage selection.

Generator Amperage

Tables 7 and 8 describe the generator’s current output capa- bility for both 1Ø-phase and 3Ø phase applications.

Table 7. Generator Ampere

Ratings — 1Ø

kW

240V

120V

 

 

 

20

83

166

 

 

 

25

104

208

30

225

250

 

 

 

35

145

291

 

 

 

40

166

333

 

 

 

45

187

375

 

 

 

50

208

417

60 (Max)

250

500

 

 

 

Figure 15. Voltage Selector Switch

Voltage Selector Switch Locking Button

The voltage selector switch has a locking button to protect the generator and load from being switched while the engine is running. To lock the voltage selector switch, press and hold the red button located at the bottom of the switch.

Table 8. Generator Ampere Ratings — 3Ø

kW

208V

240V

480V

 

 

 

 

20

59

60

30

 

 

 

 

25

87

75

38

30

104

90

45

 

 

 

 

35

121

105

53

 

 

 

 

40

139

120

60

 

 

 

 

45

156

136

68

 

 

 

 

50

174

152

76

60

208

181

99

 

 

 

 

CAUTION:

NEVER change the position of the voltage selector switch while the engine is running. ALWAYS place circuit breaker in the open position before selecting voltage.

Table 6. Voltages Available

Three Phase

208 VOLT

220 VOLT

240 VOLT

416 VOLT

440 VOLT

480 VOLT

(Switchable)

 

 

 

 

 

 

Single Phase

120 VOLT

127 VOLT

139 VOLT

240 VOLT

254 VOLT

277 VOLT

(Switchable)

 

 

 

 

 

 

PAGE 32 — DCA-70SSJU SERIES — OPERATION AND PARTS MANUAL (STD) — REV. #5 (06/03/03)