MAINTENANCE

TABLE 14. INSPECTION/MAINTENANCE

 

10 Hrs

250 Hrs

500 Hrs

 

1000 Hrs

 

DAILY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check Engine Fluid Levels

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check Air Cleaner

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check Battery Acid Level

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check Fan Belt Condition

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check for Leaks

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Check for Loosening of Parts

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace Engine Oil and Filter * 1

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

Drain Bottom of Fuel Tank

 

 

X

 

 

 

 

 

 

 

 

 

 

 

ENGINE

Check Fuel Filter/Water Seperator Bowl

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

Clean Unit, Inside and Outside

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

Check Blowby Hose * 2

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

Clean Air Filter

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

Replace Air Filter Element * 3

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

Change Fuel Filter

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

Clean Radiator and Check Coolant Protection Level

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

Check all Hoses and Clamps

 

 

 

 

 

X

 

 

 

 

 

 

 

 

 

Clean Inside of Fuel Tank

 

 

 

 

 

X

 

 

 

 

 

 

 

 

GENERATOR

Measure Insulation Resistance

 

 

X

 

 

 

 

 

 

 

 

 

 

 

Check Rotor Rear Support Bearing

 

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1

Replace engine oil anf filter at 100 hours, first time only.

 

 

 

 

 

 

*2

If blowby hose needs to be replaced, ensure that the slope of the blowby hose is at least a 1/2 inch per foot, with

 

 

no sags or dips that could collect moisture and/or oil.

 

 

 

 

 

 

*3

Replace primary air filter element when restriction indicator shows a vaccumm of 625 mm. (25 in.) H20

 

General Inspection

Prior to each use, the generator should be cleaned and inspected for deficiencies. Check for loose, missing or damaged nuts, bolts or other fasteners. Also check for fuel, oil, and coolant leaks. Use Table 14 as a general maintenance guideline. Engine Side, refer to the Engine Instruction Manual

Air Cleaner

Every 50 hours: Remove air cleaner element and clean the heavy duty paper element with kerosene, or foam element with liquid detergent and hot water. Wrap foam element in a cloth and squeeze dry. For heavy duty paper element, wipe excess kerosene with towel.

Air Cleaner with Dust Indicator

This indicator is attached to the air cleaner.When the air cleaner element is clogged, air intake restriction becomes greater and the dust indicator signal shows “RED” meaning the element needs changing. After changing the air element, press the dust indicator button to reset the indicator.

Service Daily

If the engine is operating in very dusty or dry grass conditions, a clogged air cleaner will result.This can lead to a loss of power, excessive carbon buildup in the combustion chamber and high fuel consumption. Change air cleaner more frequently if these conditions exists.

Fuel Addition

Add diesel fuel (the grade may vary according to season and locations). Always pour through the mesh filter.

Removing Water from the Fuel Tank

After prolonged use, water and other impurities accumulate in the bottom of the tank. Occasionally remove the drain cock and drain the contents.During cold weather, the more empty volume inside the tank, the easier it is for water to condense. This can be reduced by keeping the tank full with diesel fuel.

DCA25USIXF/DCA25USI2XF — OPERATION AND PARTS MANUAL — REV. #2 (07/26/11) — PAGE 37

Page 37
Image 37
Multiquip DCA25USI2XF, DCA25USIXF operation manual Maintenance

DCA25USI2XF, DCA25USIXF specifications

Multiquip is a renowned name in the construction and industrial equipment sector, known for delivering high-performance generators that cater to various power needs. Two standout models in their lineup are the DCA25USIXF and DCA25USI2XF, both designed for reliability, efficiency, and versatility.

The Multiquip DCA25USIXF is a compact, industrial-grade diesel generator that delivers a powerful 25 kVA, making it ideal for construction sites, outdoor events, and emergency backup applications. This model is powered by a robust Yanmar diesel engine, which ensures high fuel efficiency and low emissions, adhering to stringent environmental standards. The DCA25USIXF features an advanced digital control panel, providing users with an intuitive interface for monitoring performance, voltage output, and operational status. Its sound-attenuated enclosure significantly reduces noise levels, making it suitable for use in noise-sensitive areas.

On the other hand, the DCA25USI2XF model takes power generation a step further by offering dual voltage capabilities, allowing users to switch between 120V and 240V outputs. This flexibility makes it highly versatile, catering to a broader range of tools and equipment. Like the DCA25USIXF, the DCA25USI2XF is also equipped with Yanmar’s reliable diesel engine, which contributes to its durability and long service life. Both models come with a heavy-duty frame to withstand tough conditions, ensuring durability on job sites.

The technology implemented in these generators includes automatic voltage regulation (AVR), which stabilizes voltage output, protecting sensitive equipment from power surges. Additionally, the generators feature a low oil shutdown system, which prevents engine damage by automatically shutting down the generator when oil levels are low. This protective measure not only enhances the longevity of the generator but also contributes to safer operation.

In terms of portability, both models are equipped with rugged wheels and a lifting eye, facilitating easy transportation to various job sites. With their combination of power, efficiency, and advanced features, the Multiquip DCA25USIXF and DCA25USI2XF generators are excellent choices for professionals seeking reliable power solutions in demanding environments. Whether for construction, events, or standby power, these generators deliver exceptional performance tailored to meet diverse needs.