Multiquip DCA25USIXF 3Ø 480/277 Output Terminal Lug Voltages, Output Terminal Panel Connections

Models: DCA25USI2XF DCA25USIXF

1 98
Download 98 pages 10.97 Kb
Page 28
Image 28
3Ø 480/277 Output Terminal Lug Voltages

OUTPUT TERMINAL PANEL CONNECTIONS

3Ø 480/277 Output Terminal Lug Voltages

1.Place the voltage selector switch in the 3Ø 480/277 position as shown in Figure 26.

Figure 26. Voltage Selector Switch 480/277V

Three-Phase Position

1Ø 240V/120V Output Terminal Lug Voltages

1.Place the voltage selector switch in the 1Ø 240/120 position as shown in Figure 28.

Figure 28. Voltage Selector Switch 240/120V

Single-Phase Position

2.Connect the load wires to the OutputTerminal Lugs as shown in Figure 27.

2.Connect the load wires to the OutputTerminal Lugs as shown in Figure 29.

Figure 27. Output Terminal Lugs

Figure 29. Output Terminal Lugs

3Ø-480/277V Connections

1Ø-240/120V Connections

3.Turn the voltage regulator knob (Figure 23) clockwise to increase voltage output, turn counterclockwise to decrease voltage output.

3.Turn the voltage regulator knob (Figure 23) clockwise to increase voltage output, turn counterclockwise to decrease voltage output.

PAGE 28 — DCA25USIXF/DCA25USI2XF — OPERATION AND PARTS MANUAL — REV. #2 (07/26/11)

Page 28
Image 28
Multiquip DCA25USIXF, DCA25USI2XF 3Ø 480/277 Output Terminal Lug Voltages, 1Ø 240V/120V Output Terminal Lug Voltages