MAINTENANCE

 

Table 12. Inspection/Maintenance

10 Hrs

250 Hrs

500 Hrs

1000

 

DAILY

Hrs

 

 

 

 

 

Check Engine Fluid Levels

X

 

 

 

 

Check Air Cleaner

X

 

 

 

 

Check Battery Acid Level

X

 

 

 

 

Check Fan Belt Condition

X

 

 

 

 

Check for Leaks

X

 

 

 

 

Check for Loosening of Parts

X

 

 

 

 

Replace Engine Oil and Filter * 1

 

X

 

 

Engine

Clean Air Filter

 

X

 

 

 

Check Fuel Filter/Water Separator Bowl

X

 

 

 

 

Clean Unit, Inside and Outside

 

X

 

 

 

Change Fuel Filter

 

 

X

 

 

Clean Radiator and Check Coolant Protection Level*2

 

 

X

 

 

Replace Air Filter Element * 3

 

 

X

 

 

Check all Hoses and Clamps * 4

 

 

 

X

 

Clean Inside of Fuel Tank

 

 

 

X

Generator

Measure Insulation Resistance Over 3M ohms

 

X

 

 

Check Rotor Rear Support Bearing

 

 

X

 

 

 

 

 

*1

Replace engine oil and fi lter at 100 hours, fi rst time only.

 

 

 

 

*2

Add “Supplemental Coolant Additives (SCA’S)” to recharge the engine coolant.

 

 

*3

Replace primary air fi lter element when restriction indicator shows a vacuum of 625 mm (25 in. H20).

*4

If blowby hose needs to be replaced, ensure that the slope of the blowby hose is at least a 1/2 inch per foot,

 

with no sags or dips that could collect moisture and/or oil.

 

 

 

 

GENERAL INSPECTION

Prior to each use, the generator should be cleaned and inspected for defi ciencies. Check for loose, missing or damaged nuts, bolts or other fasteners. Also check for fuel, oil, and coolant leaks. Use Table 12 as a general maintenance guideline. Engine Side, refer to the Engine Instruction Manual.

AIR CLEANER

Every 250 hours: Remove air cleaner element (Figure 62) and clean the heavy duty paper element with light spray of compressed air. Replace the air cleaner as needed.

Air Cleaner with Dust Indicator

This indicator (Figure 62) is attached to the air cleaner. When the air cleaner element is clogged, air intake restriction becomes greater and the dust indicator signal shows RED meaning the element needs changing or service. After changing the air element, press the dust indicator button to reset the indicator.

Figure 62. Air Cleaner/Indicator

NOTICE

The air fi lter should not be changed until the indicator reads “RED”. Dispose of old air fi lter. It may not be cleaned or reused.

PAGE 38 — DCA800SSK2 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV. #0 (09/03/09)

Page 38
Image 38
Multiquip DCA800SSK2 manual Maintenance, General Inspection AIR Cleaner, Air Cleaner with Dust Indicator

DCA800SSK2 specifications

The Multiquip DCA800SSK2 is a robust and versatile portable diesel generator, designed to meet the demands of a wide range of applications. With a powerful 800 kW (kilowatt) capacity, it is particularly suited for use in construction sites, events, and emergency backup power situations. This generator combines reliability, durability, and ease of use, making it a popular choice among contractors and rental companies.

One of the main features of the DCA800SSK2 is its advanced sound attenuation technology. This ensures that the generator operates quietly, minimizing noise pollution while maximizing performance. The enclosure is designed to reduce sound levels without compromising on the cooling requirements, which extends the overall lifespan of the generator. Users can expect noise levels well within acceptable limits for urban and residential areas.

The DCA800SSK2 is equipped with a state-of-the-art digital controller that offers enhanced monitoring and diagnostic capabilities. This intelligent control system enables users to track key performance metrics, such as voltage, frequency, and operating hours, all from a user-friendly interface. Furthermore, it includes automatic shutdown features for low oil pressure, high temperature, and overcurrent situations, providing an added layer of safety and preventing potential damage.

Fuel efficiency is another standout characteristic of the Multiquip DCA800SSK2. With a large fuel tank, it can operate for extended periods without frequent refueling, making it ideal for long-term use in remote areas where access to fuel may be limited. The generator's engine is engineered to provide optimal fuel consumption, ensuring that operators can maximize their running time while minimizing operational costs.

The DCA800SSK2 includes multiple outlets for electricity distribution, allowing users to connect various tools and equipment simultaneously. This versatility makes it suitable for a wide range of applications, from powering heavy machinery on construction sites to providing backup power for critical infrastructure.

Overall, the Multiquip DCA800SSK2 stands out in the market for its combination of power, efficiency, and advanced features. With its robust build quality, innovative technologies, and user-centric design, it is an excellent choice for anyone in need of a reliable portable generator. Whether for professional use or emergency situations, the DCA800SSK2 delivers outstanding performance and peace of mind.