MAINTENANCE

CAUTION

DO NOT replace fi lter immediately, allow a suffi cient amount of time for the lamp assembly to cool down before changing fi lter

FILTER REPLACEMENT

1.Remove the balloon as described in the "Removing the Lamp/Balloon" section.

2.Disconnect the lamp power cable (Figure 5).

3.Rotate the balloon/lamp base assembly so that the fi lter is facing upwards. See Figure 26.

BALLOON/LAMP

Figure 26. Balloon/Lamp Placement

4.Turn the three locking tabs (Figure 27) inward to release the plate. Remove plate and fi lter.

PLATE

FILTER

TURN

OUTWARD

TO RELEASE

LOCKING

TAB

Figure 27. Filter Removal

5.Install a new fi lter over the brace as shown in Figure 28. Be sure to align the cut of the fi lter over the brace.

BRACE

FILTER

CUT

Figure 28. Filter Placement

CAUTION

When placing the fi lter element, always align the cut of the fi lter on top of the brace. This will keep the fi lter from being dislodged and getting damaged.

6.Turn the three retaining tabs (Figure 29) outward so that they touch the lamp base.

PLATE

FILTER

TURN

INWARD

TO LOCK

LOCKING

TAB

Figure 29. Filter/Plate Install

GB114BS/BP GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #3 (01/06/09) — PAGE 23