GLOBUG SOLO LIGHTING SYSTEM — COMPONENTS

Figure 6 shows the location of the controls and components for the GloBug Solo Lighting System. The function of each control is described below:

1.Mast – This mast is comprised of three separate stages (four - with extension pole). The mast can be raised in excess of 16.5 ft. (5 meters). When raising the mast, always be on the lookout for overhead obstructions. Never adjust the mast with the balloon off to prevent mast from shooting up and causing injury.

2.Mast Release Latch– Use this latch to raise the mast by pushing down the mast and then releasing the latch. Always be on the lookout for overhead obstructions. Keep immediate area free of bystanders and debris when raising the mast.

3.Mast Lock Lever – Use this lock to keep mast in place after the mast height has been adjusted.

4.Ballast – Provides the necessary electronics to light the lamp.

5.AC Power Cable – Connect this cable to a 120 VAC, 60 Hz power source.

6.Outriggers – ALWAYS deploy the outriggers when raising the mast.

7.Counter-Weight Lever – Locks the outriggers in place when they are deployed.

8.Wheels – The GloBug Solo uses 5 caster wheels. To prevent the Globug Solo from moving, always lock 3 caster wheels.

9.ON/OFF Switch – Place this switch in the ON position to turn on the lamp.To turn off the lamp place in the OFF position. Please wait for approximately 10 minutes be- fore attempting to turn the lamp back on.

10.Balloon – This balloon is made of heat-resistant nylon, with a diameter of 3.9 ft.(1,150 mm).The balloon shall be inflated to a pressure of 31.26 psi (215.6 kPA).

11.Balloon Cover – Covers the balloon when not in use. Allow a sufficient amount of time for the lamp to cool down before covering balloon. Possibility exists of bal- loon getting burned.

12.Extension Pole – extends the height of the mast when needed.

13.Lamp Power Cable (Ballast) – Connect this quick- disconnect cable plug (ballast-side) to the balloon lamp power cable plug.

14.Lamp Power Cable (Balloon) – Connect this quick- disconnect cable plug (balloon-side) to the ballast lamp power cable plug.

15.Lamp Guard – This guard (cage) protects the lamp from being hit by objects.

16.Lamp – 1000 watt metal-halide type lamp. Replace only with MQ recommended type lamp. Always allow a sufficient amount of time for the lamp to cool down before changing.

17.Lamp Holder – Screw lamp into this holder. If lamp becomes difficult to screw into holder or holder is damaged, replace holder.

18.Fan Motor (Blower) – This electric motor is responsible for inflating the balloon. It will supply a pressure of 31.26 psi (215.6 kPA). Please note that the balloon will begin to inflate as soon as power is applied to the GloBug Solo. The OFF/ON switch does not control the electric fan motor.

19.T-Handle Bolt Lock – Always tighten this lock to hold the lamp/balloon securely in place before raising mast.

20.Balloon Alarm Buzzer – Will sound during normal operation if the balloon attempts to make contact with the lamp's hot surface. If this condition occurs, immediately place the GloBug Solo's ON/OFF switch in the OFF position.

GB114BW GLOBUG SOLO LIGHTING SYSTEM — OPERATION & PARTS MANUAL — REV. #5 (01/06/09) — PAGE 15