PAGE 20 — GB114BW GLOBUG SOLO LIGHTING SYSTEM — OPERATION & PARTS MANUAL — REV. #5 (01/06/09)
GLOBUG SOLO LIGHTING SYSTEM — MAINTENANCE
Removing the Lamp/Balloon Assembly
1. Loosen the T-Handle Bolt Lock (Figure 22) that secures the
lamp to the mast.
3. Disconnect the lamp power cable (Figure 6) and slide the
balloon/lamp forward from the mast adapter stand. Place
lamp/balloon assembly on a suitable work bench that is
free of dirt, and sharp objects that could damage the
balloon.
Removing the Lamp
1. Expose the balloon (Figure 23) by pulling down on the
velcro tabs and unzip the protective cover as shown in
Figure 19. Next, fold the protective cover into itself and
zip.
Figure 22. Loosening the Balloon/Lamp
Figure 23. Exposing the Balloon
Figure 24. Removing the Lamp Guard
3. Push down and hold the lamp holder (spring loaded) away
from the lamp (Figure 25). Unscrew the lamp (turn
counterclockwise) from the lamp socket.
Figure 25. Removing the Lamp
CAUTION - READ SAFETY GUIDELINES
Before performing any maintenance
procedures, be sure to READ the lamp,
balloon, and general safety guidelines in
this manual. Failure to
read
and
understand
these safety guidelines
could cause severe equipment damage
and bodily harm.
CAUTION - BALLOON ZIPPER SAFETY
DO NOT use excessive force when zipping or
unzipping the balloon. The possibility exists
of the zipper tearing, which would make the
balloon unusable.
2. Unzip the zipper (Figure 23) at the bottom of the balloon
and roll the balloon envelope upwards to expose the lamp
(Figure 24). Remove the lamp guard to gain access to the
lamp.. DO NOT use excessive force when unzipping the
balloon.