GLOBUG SOLO LIGHTING SYSTEM —TROUBLESHOOTING (LAMPS)

Practically all breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, please take a remedial action following the diagnosis based on the Lamp Troubleshooting (Table 4) information shown below.

If the problem cannot be remedied, please leave the unit just as it is and consult or company's service department.

TABLE 4. LAMP TROUBLESHOOTING

SYMPTOM

POSSIBLE PROBLEM

SOLUTION

 

 

 

 

Is plug disconnected?

Plug in correctly.

 

 

 

 

Is lamp power switched off?

Turn on switch.

 

 

 

 

Is lamp loose?

Screw lamp securely into socket.

 

 

 

 

Is contactor disconnected or loose?

Connect disconnected contactor.

 

 

 

Lamp does not light.

Are any other electric appliances (other

 

than light tower) plugged into power

Unplug all other appliances.

 

 

source?

 

 

 

 

 

Is model of lamp incompatible?

Use genuine MQ lamp.

 

 

 

 

Is lamp not cool enough to light again?

 

 

(Interval of 20 to 30 minutes is required

Wait for lamp to cool down.

 

before turning on lamp again)

 

 

 

 

Lamp only lights for a

Is ambient temperature too high (more than

Move lamp where there is proper

short time.

104 °F (40 °C)?

ventilation.

 

 

 

Balloon does not

Is fan motor (blower) not working properly?

Check or repair fan motor (blower).

 

 

inflate.

Is balloon envelope defective?

Repair or replace balloon envelope.

 

 

 

 

PAGE 26 — GB114BW GLOBUG SOLO LIGHTING SYSTEM — OPERATION & PARTS MANUAL — REV. #5 (01/06/09)

Page 26
Image 26
Multiquip GB114BW manual Globug Solo Lighting System -TROUBLESHOOTING Lamps