Multiquip LS500, LS400 manual Wheel Bearings, Extended Storage Instructions, Pressure Test

Models: LS500 LS400

1 148
Download 148 pages 21.18 Kb
Page 43
Image 43

LS400/LS500 PUMP — MAINTENANCE (PUMP)

WHEEL BEARINGS

After every 6 months of operation inspect the wheel bearings. Once a year, or when required, disassemble the wheel hubs remove the old grease and repack the bearings forcing grease between rollers, cone and cage with a good grade of high speed wheel bearing greases (never use grease heavier than 265 A.S.T.M. penetration “No. 2.”).

1.Fill the wheel hub with grease to the inside diameter of the outer races and also fill the hub grease cap.

2.Reassemble the hub and mount the wheel.Then tighten the adjusting nut, at the same time turn the wheel in both directions, until there is a slight bind to be sure all the bearing surfaces are in contact.

3.Back off the adjusting nut 1/6 to 1/4 turn or to the nearest locking hole or sufficiently to allow the wheel to rotate freely within limits of .001” to .010” end play. Lock the nut at this position.

4.Install the cotter pin and dust cap, and tighten all hardware.

EXTENDED STORAGE INSTRUCTIONS

The following preventative maintenance is recommended for extended periods of storage.

1.Check brake system for proper fluid level in master cylinder and bleed all lines.

2.Lubricate all links and pivots to prevent any rusting.

3.Remove wheel and drum assemblies and spray a good anti-corrosion compound (CRC formula 5-56) under rubber boot on forward end of brake wheel cylinder. Avoid spraying drum and brake lining.

4.Grease all bearings and reinstall wheel and drum assemblies.

5.Make sure breakaway cable is fully released.

6.After extended storage, refer to the Maintenance Steps listed above to insure that the trailer is ready for towing.

PRESSURE TEST

1.To determine the pressure of the Hydraulic System, set the Cylinder Stroke Control Switch (Figure 42) to the JOG position.

Figure 42. Cylinder Stroke Control Switch (JOG)

2.Turn and hold the Manual Cylinder Jogging Switch (Figure 43) to either JOG “A” or JOG “B” position to test the pressure of that cylinder.

Figure 43. Manual Cylinder Jogging Switch

13.The Pumping Pressure Gauge (Figure 44) should read approximately 4400 ± 50 PSI.

Figure 44. Pumping Pressure Gauge

MAYCO LS400/LS500 PUMP — OPERATION AND PARTS MANUAL — REV. #6 (09/19/11) — PAGE 43

Page 43
Image 43
Multiquip LS500, LS400 Wheel Bearings, Extended Storage Instructions, Pressure Test, Cylinder Stroke Control Switch JOG