STARTING THE ENGINE

The LT12 Series Light Tower is available with two types of engines (Perkins or Lombardini/Deutz).The engine starting procedure for both engines are described below.

Starting the Engine (Perkins)

1.Open the access panel door on the right side of the light tower (opposite the fuel tank). Set the door latch in place to hold the door open (up).

2.Insert the ignition key into the ignition key switch (Figure 14). Turn the ignition key clockwise to the ON position. The preheat indicator lamp will light. Wait for this indicator lamp to go OFF. When the indicator lamp goes OFF, the glow plugs have been preheated and the engine can now be started.

*EMERGENCY SHUT DOWNS *

 

 

 

Flashing LED Indicates

 

 

 

Cause of Shut Down

 

WATER TEMP

 

OIL PRESSURE

 

AIR FILTER

 

PRE-HEAT

IGNITION

INDICATOR

When Light Goes Out

 

When Flashing

KEY

Indicate Start

 

Indicates Low Battery Charge

 

 

 

SWITCH

 

OFF

N

 

 

 

O

 

 

 

S

 

 

 

T

 

 

 

A

 

 

 

R

 

 

 

T

Figure 14. Ignition Key Switch (Perkins Engine)

3.Continue turning the ignition key in a clockwise direction to the START position. When the engine has started, release the key.

4.Before placing the light tower into actual operation, let it run for 3-5 minutes. Check for any abnormal sounds or smells that would be associated with a defective light tower. If any abnormal conditions occur, shut down the light tower and correct the problem.

OPERATION

Starting the Engine (Lombardini/Deutz Engines)

1.Open the access panel door on the right side of the light tower (opposite the fuel tank). Set the door latch in place to hold the door open (up).

2.Insert the ignition key into the ignition key switch (Figure 15). Turn the ignition key clockwise one click to the ON position. The preheat indicator lamp will light. Wait for this indicator lamp to go OFF. When the indicator lamp goes OFF, the glow plugs have been preheated and the engine can now be started.

LOMBARDINI

IGNITION

KEY

SWITCH

Figure 15. Ignition Key Switch (Lombardini/

Deutz Engine)

3.Continue turning the ignition key all the way clockwise When the engine has started, release the key.

4.Before placing the light tower into actual operation, let the engine run for 3-5 minutes. Check any abnormal sounds or smells that would be associated with a defective light tower. If any abnormal conditions occur, shut down the light tower and correct the problem.

PAGE 26 — LT12 SERIES LIGHT TOWER • OPERATION MANUAL — REV. #12 (01/20/09)

Page 26
Image 26
Multiquip LT12D, LT12P Operation, Starting the Engine Perkins, Starting the Engine Lombardini/Deutz Engines