INSPECTION
FUEL CHECK
CAUTION
Diesel fuel and its vapors are dangerous to your health and the surrounding environment. Avoid skin contact and/or inhaling fumes. DO NOT smoke while refueling. DO NOT attempt to refuel the
light tower if the engine is hot or running.
1.To check the engine fuel level, make sure the light tower is placed on secure level ground with the engine stopped.
2.Lift the light tower access door (Figure 7) opposite the control panel. Set the door support latch in place to keep the door open (up).
Figure 7. Adding Fuel
3. Remove the fuel cap from the fuel tank.
CAUTION
ALWAYS fill the fuel tank with clean, fresh #2 diesel fuel. DO NOT fill the fuel tank beyond its capacity. DO NOT
4.Pay attention to the fuel tank capacity when replenishing fuel.The fuel tank cap must be closed tightly after filling. Handle fuel in a safe container. If the container does not have a spout, use a funnel.
5.Wipe up any spilled fuel immediately!
BATTERY CHECK
WARNING
The operator must wear the appropriate protective equipment and clothing while handling the battery.
Failure to wear protective equipment or clothing could result in serious injury.
The
Figure 8. Battery
When servicing of the battery is required, perform the following:
A face shield and rubber gloves should be worn while handling and servicing the battery's electrolyte.
Disconnect battery terminal clamps, and remove the battery from the generator cabinet when servicing is required.
DO NOT overfill the battery.
WARNING
Electrolyte is an acid and must be handled with caution. ALWAYS follow servicing instructions from the electrolyte manufacturer to ensure safety. Serious
injury can result from careless handling and noncompliance to safety handling instructions.
Overfi lling the battery may cause the electrolyte to overflow resulting in corrosion to nearby components. Immediately wash off any spilled electrolyte (battery acid).
LT12 SERIES LIGHT TOWER • OPERATION MANUAL — REV. #12 (01/20/09) — PAGE 23