WARNING

The engine's exhaust contains harmful emissions. ALWAYS ventilate the exhaust when operating inside tunnels, excavations or buildings. Direct exhaust away from nearby personnel.

Before starting the engine, make sure of the following:

The electrical load is disconnected and the main circuit breaker and all lamp (4) circuit breakers are switched to the OFF position.

CAUTION

NEVER start the engine with any circuit breakers in the ON position.

Light tower is placed on secure level ground with chock blocks underneath each wheel to prevent the light tower from rolling.

Outriggers have been fully extended to prevent the trailer from tipping.

Light tower trailer support stands have been positioned properly and the trailer is level.

Lamps have been adjusted to desired position.

Chocked blocks have been positioned under each wheel to prevent trailer from rolling.

Light tower trailer frame has been grounded correctly.

Lamps do not interfere with any overhead obstructions.

DANGER

ALWAYS make sure the area above light tower is open and clear of overhead power lines and other obstructions. The tower extends in excess of 30 ft. (9 meters). Contact with overhead power lines or other obstructions could result in equipment damage, serious injury or death!

Lamp power cables have been plugged into the appropriate receptacles (J1-J4) on the T-Bar assembly. Follow instructions below to correctly install the power cable plugs.

INSPECTION

a.Locate the 4 key-lock female 3-pin DIN connectors on the T-bar. See Figure 10.

KEY-LOCK

FEMALE

CONNECTORS

Figure 10. Location of Female Connectors

b.Locate the slot or key (A) on each female connector as shown in Figure 11.

Figure 11. Female Connector

c. On the corresponding male connector, locate the key tab (B) as shown in Figure 12.

B

Figure 12. Male Connector

d.Align the key tab (B) on the male connector with the slot or key (A) on the female connector and press together until seated.

e.Secure the connector by screwing the knurled locking nut of the male connector to the threaded portion of the female connector to ensure good contact between the two connectors. See Figure 13.

LOCKING

NUT

J1

J2

J3

 

 

J4

 

 

 

 

 

Figure 13. Cable Connectors

LT12 SERIES LIGHT TOWER • OPERATION MANUAL — REV. #12 (01/20/09) — PAGE 25

Page 25