OPERATION

APPLYING AN EXTERNAL LOAD

The light tower is equipped with two auxiliary output receptacles (Figure 19). The uppermost receptacle (twist- lock) located at the front of the light tower can provide 240 VAC at 25 amps. The bottom receptacle is a GFCI receptacle which can supply 120 VAC at 15 amps.

Figure 19. Auxiliary Output Receptacles

DANGER

NEVER grab or touch a live power cord with wet hands. The possibility exists of electrical shock, electrocution, and even death!

TESTING THE 120 VAC GFCI RECEPTACLE

Pressing the reset button resets the GFCI receptacle after being tripped. Pressing the test button (See Figure 20) in the center of the receptacle will check the GFCI function. Both receptacles should be tested at least once a month.

Figure 20. GFCI Test Button

NORMAL SHUTDOWN

1.If a load is attached to the generator of the light tower, remove the load.

2.Set the four lamp circuit breakers on the control panel to the OFF position.

3.Place the MAIN circuit breaker on the control panel to the OFF position.

4.Wait a few seconds and observe that all four lamps are OFF.

5.Let the engine idle for a few minutes with no load.

6.Turn the ignition key to the OFF position. Store key in a safe location.

7.Lower light tower mast and place in stow position as outlined in this manual.

8.Place outriggers in tow position, and remove chock blocks.

9.Store light tower in a clean, dry location out of the reach of children and unauthorized personnel.

NOTICE

If servicing is required, allow lamps to cool for about 15 minutes before removing lamps.

EMERGENCY SHUTDOWN

1.Turn the ignition key to the OFF position and turn all circuit breakers to the OFF position.

PAGE 30 — LT12 SERIES LIGHT TOWER • OPERATION MANUAL — REV. #12 (01/20/09)

Page 30
Image 30
Multiquip LT12D, LT12P Applying AN External Load, Testing the 120 VAC Gfci Receptacle, Normal Shutdown, Emergency Shutdown