PRE-SETUP (GASOLINE)
PRE-SETUP
WARNING
Whenever cleaning, adjusting or lubricating any part of the saw, MAKE CERTAIN to stop the engine and disconnect the spark plug wire from the spark plug.
Assembly (Gasoline Powered Saws Only)
1.Remove the MP1 saw from its container and place it on a suitable table or platform. Make sure the table or platform can support the weight of the saw.The saw platform should be rigid and stationary so that it will not move, sag, or sway due to the vibrations and movements of the saw.
2.If using the MP1 series support stand kit (P/NTRAK14SS), attach stand to the
3.The gasolinepoweredsawusesamechanicalwaterpump. This pump operates by drawing power from the
4.Fill the water tray with clean fresh water. The water pump intake (strainer) must always be fully covered by water to operate effectively. Also, keep the pump intake free of sludge, debris and other materials that may accumulate in the tray.
5.Make certain that the water hose will not come in contact with the blade or interfere with any moving parts. The best location for the water pump/strainer is between the splash shield and the rear of the water tray. This will prevent some of the abrasive particles from flowing through the pump.
CAUTION
ALWAYS position the strainer in the water tray in a manner that will allow the free movement of the conveyor cart, and clearance from the cutting blade and cutting action.
The MP1 gasoline model utilizes some of the same procedures that are used for the MP1 electric models. Please reference pages
20 and 21 for the below referenced procedures:
■Conveyor Cart Placement
■Blade Selection and Inspection
■Saw Blades
■Blade Installation
DRY CUTTING (GASOLINE ONLY)
To disconnect the mechanical water pump from the drive V- belts perform the following:
1.Loosen the 2 hex head cap screws (Figure 15) that secure the pump mount bracket.
2.Pull the pump handle upward to disengage the pump.
3.Tighten the 2 hex head cap screws that secure the pump mount bracket.
Figure 15. Pump Disengage
WET CUTTING (GASOLINE ONLY)
To connect the mechanical water pump to the drive
1.Loosen the 2 hex head cap screws (Figure 16) that secure the pump mount bracket.
2.Push the pump handle downward to engage the pump.
3.Tighten the 2 hex head cap screws that secure the pump mount bracket.
The mechanical water pump is
NOTEshipped from the factory for wet cutting applications.
Figure 16. Pump Engage
PAGE 24 — MP1 — OPERATION AND PARTS MANUAL — REV. #3 (03/29/10)