MODULE CONFIGURATION SETTINGS
In order for the 900 Series modules to communicate properly the chassis must be populated with modules from the top slot down as shown below. In addition, JP1 and JP2 jumpers (located on top side of all modules) must be configured as indicated below.
Note: The power source must be disconnected from the 900B chassis prior to removing and inserting modules. This unit is not hot swappable.
One Slot Configuration - When installing a single 902FX, 904FX, or 908TX module in the top slot of the 900B chassis… Configure the module as follows:
JP1: pins 1 & 2 shorted
JP2: pins 1 & 2 shorted
Two Slot Configuration - When installing two 902FX, 904FX, and/or 908TX modules in the top two slots of the 900B chassis… Configure both modules as follows:
JP1: pins 1 & 2 shorted
JP2: pins 3 & 4 shorted
Three Slot Configuration - When installing three 902FX, 904FX, and/or 908TX modules in all three slots of the 900B chassis… Configure all modules as follows:
JP1: pins 3 & 4 shorted
JP2: pins 3 & 4 shorted
908TX Module - At power cycle, all LED’s flash on for approximately two seconds, and
then return to proper state. Green LED will light when Power is connected.
902FX & 904FX Modules - At power cycle, only the LED’s on the first port flash on to indicate the reset condition, and then return to their proper state. All other reports remain
off during reset. This is normal behavior. Green LED will light when Power is connected.
4/26/2007 | 10 |