INTRODUCTION
The
SPECIFICATIONS
Operating Voltage: 12 V DC (supplied by panel)
Current Drain:50 mA Standby
Dimensions: 4 3/8” x 5 7/8” x 11/16”
Note: Subtract keypad current from combined auxiliary current of the control panel.
MOUNTING THE KEYPAD
A keypad should be located near each exit/entry door. To open the case, insert a screwdriver into either slot at the bottom and push up with a slight twisting motion to release the retainer tab. Repeat for the other slot. Pull out at the bottom and lift off the two hooks at the top.
The
If installing onto a
WIRING | COLOR | TERMINAL |
|
Connect the keypad wires to the control panel | RED | 9 |
|
terminals shown in the table at the right. | BLACK | 10 |
|
|
|
| |
GREEN | 11 |
| |
Caution: Do not run keypad wiring with loop wiring. |
| ||
|
|
| |
YELLOW | 12 |
| |
KEYPAD CONFIGURATION |
| ||
|
|
| |
WHITE | N/O PANIC | * Cut and insulate 2 white wires if not used. | |
Up to 7 | WHITE | N/O PANIC | |
the control panel (Keypads |
|
| ured for a keypad address. In addition, |
the keypad may be configured to disable touchpad backlight and entry sounder. Keypads are configured by the proper selection of jumpers. Refer to the label on the keypad circuit board for jumper locations and a summary of settings.
KEYPAD ADDRESS
If more than one keypad is installed:
∙Each must be assigned a unique address (that is, no two keypads may be numbered alike).
∙Keypads must be addressed consecutively (that is, missing numbers are not permitted).
∙Only Keypad No. 1 may be used for programming. (However, for ease of programming, it is recommended that a
∙Assign the keypad address number by selecting Jumpers
*Note: (1) Keypads are factory supplied with no jumpers installed and a as such are automatically configured as Key- pad No. 1. (2) Only one keypad in the system may be configured as Keypad No. 1, otherwise none will function.
TOUCHPAD BACK LIGHT
Cut Jumper A to disable touch pad back lighting.
DISABLE SOUNDER
Cut Jumper C to disable the sounder. (Do not disable in UL applications.)
ENABLE KEYPAD TAMPER
Cut Jumper D to enable Keypad Tamper.
ENABLE TAMPER LED
Cut Jumper E to covert the Keypad CHIME LED to a SYSTEM TAMPER LED. (Only on control panels which support system tamper)
KEYPAD |
| JUMPER SETTINGS | ||
NUMBER | 1 | 2 | 3 | PARK |
1 | OFF or | ∙ | ∙ |
|
| ON |
|
|
|
2 | ∙ | ON |
| STORE SPARE |
3 | ON | ON |
| JUMPERS |
4 | ∙ | ∙ | ON | IN THIS |
5 | ON | ∙ | ON | POSITION |
6 | ∙ | ON | ON |
|
7 | ON | ON | ON |
|
For Sales and Repairs, call toll free: (800) 645-9445
For direct line to Technical Service, call toll free: (800)
Internet: http://www.napcosecurity.com