Number of Keypads in Area 1

Programming the GEM-P816 & GEM-P1632

07

INTERIOR

BYPASS

FIRE/TBL SYS TBL

CHIME

 

INTERIOR BYPASS

FIRE/TBL SYS TBL

CHIME

Entry/Exit Zones in Area 1 (Appears for New Panel Only)

Press the Abutton and then directly enter the zone number of any zones

which are to be used as Entry/Exit zones. Valid entries are from 01 to 32. Di- rectly enter each zone number, including leading zeros.

Use number buttons 0through 9.

Press Jto save and then repeat for any additional zone(s). Press NEXT (E) button to proceed. NOTE: Chime will automatically be programmed for all E/E zones.

(Direct Entry)

08

INTERIOR

BYPASS

FIRE/TBL SYS TBL

CHIME

 

INTERIOR BYPASS

FIRE/TBL SYS TBL

CHIME

(Direct Entry)

Interior Zones in Area 1 (Appears for New Panel Only)

Press the Abutton and then directly enter the zone number of any zones

which are to be used as Interior Zones. Valid entries are from 01 to 32. Di- rectly enter each zone number, including leading zeros. Use number buttons

0through 9. Press Jto save and then repeat for any additional

zone(s). Press NEXT (E) button to proceed. NOTE: All Interior zones will also be automatically programmed as “Exit/Entry Follower” zones.

09

INTERIOR

BYPASS

FIRE/TBL SYS TBL

CHIME

 

INTERIOR BYPASS

FIRE/TBL SYS TBL

CHIME

(Direct Entry)

Number of Keypads in Area 1

Press the Abutton and then directly enter the total number of Keypads to

be installed in Area 1. Valid entries are from 01 to 07. Directly enter the number of keypads, including leading zeros. Use number buttons 0

through 9. Press Jto save . Press NEXT (E) button to proceed.

NOTE: Area 2 keypads can only be assigned in Direct Address Programming. See Keypad Options.

11

INTERIOR

BYPASS

FIRE/TBL SYS TBL

CHIME

 

Central Station Receiver 1 Telephone Number

Press the Abutton and using the number buttons, directly enter telephone number of up to 16 digits including prefix, if necessary, for receiver 1.

 

 

INTERIOR BYPASS

FIRE/TBL SYS TBL

CHIME

 

 

 

 

 

 

 

(Direct Entry)

Central Station Receiver 1 Telephone Number

NOTE: Central Station Receiver 2 and 3 Telephone Numbers can be entered in Direct Address Programming. See CS Reporting Options.

Press Jto save . Press NEXT (E) button to proceed.

12 INTERIOR

BYPASS

FIRE/TBL SYS TBL

CHIME

 

 

 

INTERIOR BYPASS

FIRE/TBL SYS TBL

CHIME

(Direct Entry)

Central Station Receiver 1 Account Number

Press the Abutton and then directly enter an account number of up to four digits.

Central Station Account #

NOTE: Central Station Receiver 2 and 3 Account Numbers can be entered in Direct Address Programming. See CS Reporting Options.

For Central Station Telephone and Account Numbers: Use number buttons 1 through 9 for digits 1–9; press

G0 for a zero and G1 through G5 for letters B–F, respectively. NOTE: Pre-Dial Delay = “D”; Dial-Tone Detection = “E”. Pressing the0button will produce a blank space (•).