Programming the GEM-P816 & GEM-P1632

13

INTERIOR

BYPASS

FIRE/TBL SYS TBL

CHIME

 

INTERIOR BYPASS

FIRE/TBL SYS TBL

CHIME

(Direct Entry)

Central Station Receiver 1 Format

From the table below, enter the central station's receiver format. Use number buttons 1through 9. NOTE: Press G0for a zero and 0

for a blank space (•). Press G1through G4for letters B–E,

respectively. Press Jto save. Press NEXT (E) button to proceed.

NOTE: Central Station Receiver 2 and 3 Formats can only be entered in Direct Address Programming. See CS Receiver Options.

DATA

CS RECEIVER 1 FORMAT

ENTRY

 

 

 

•(blank)

Ademco Slow, Silent Knight Slow

 

 

2

Radionics Fast

 

 

3

Silent Knight Fast

 

 

4

Radionics, CD, Franklin Slow

 

 

DATA

CS RECEIVER 1 FORMAT

ENTRY

 

 

 

5

Universal High Speed

B

SIA

C

Ademco Point ID

 

 

E

Pager

 

 

14

INTERIOR

BYPASS

FIRE/TBL SYS TBL

CHIME

 

 

 

INTERIOR BYPASS

FIRE/TBL SYS TBL

CHIME

 

 

 

 

 

 

 

(Direct Entry)

User #

User Code

Enter User Codes

For default program, enter up to 32 User Codes, with Area 1 and Area 2 Options.Press the (A) button once to set the cursor to the User Code.

Use the number buttons 0 through 9 to enter the User Number, followed by a User Code of up to 6 digits. Enter G0for a blank.

NOTE: If “Enable Global Ambush Code”(Address 0720) is enabled and “Global Ambush Code” (Address 1054) is left blank(•),do not program the first two digits of ANY User Code as '99'.

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: When entering the Area 1 and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Area 2 options, press G0for a

 

 

 

 

 

 

 

 

 

 

 

 

 

ten. Enter 0for a blank.

Area 1

 

 

 

Area2

 

 

 

 

Options

 

 

 

Options

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USER AREA OPTIONS - Select the desired Area Options (Area 1 and Area 2) from the table below.

DATA ENTRIES

OPTION ENABLED

 

 

 

 

 

L

R

 

EXPLANATION

 

 

 

 

blank(•)

blank(•)

Disabled

User Code not active in this area.

 

 

 

 

blank(•)

1

Arm/Disarm

Allows User Code to arm/disarm this area.

 

 

 

 

blank(•)

2

Arm Only

Prevents User Code from disarming this area.

 

 

 

 

blank(•)

3

Service

A Service Code has restricted arm/disarm rights; if an area is armed with a Service Code, the area can be disarmed

 

 

 

with any valid User Code, including a Service Code. If the area is armed with OTHER than a Service Code, it CANNOT

 

 

 

be disarmed with a Service Code.

blank(•)

4

Access

This is normally used to activate a door striker while an area is disarmed. Also program “Access Control on PGM2

 

 

 

Output” (Address 0719) and “PGM2 Output Access Control Timeout” (Address 0711).

blank(•)

Add 8

* User Program

User Program Option is enabled for Keypad 1 only, wherever it is connected (Area 1 or Area 2).

 

 

 

 

Press Jto save. To proceed to the next User Code, press the Abutton to set the cursor to the User Number and change it using the number buttons.

If the programmed code was less than 6 digits, enter blanks G0for the remaining digits.

Example: Program a code of “2222” for user 02, with area 1 options of “Arm/Disarm” and “User Program”:

Enter 02for the user number, 2222 G0 G0for a user code, G09“(blank) 9” for area 1 options andG0G0“(blank) (blank)” for area 2 options.

CHANGING OR CANCELING A CODE: To change any code, merely program over the existing code as described above and press Jto save. Similarly, to cancel a code, blank out each number of the code press Jto save.

7

Page 7
Image 7
Napco Security Technologies GEM-P9600, GEM-P816, GEM-P1632 quick start Central Station Receiver 1 Format, Enter User Codes

GEM-P9600, GEM-P816, GEM-P1632 specifications

Napco Security Technologies is known for its innovative and robust security solutions, and its GEM series control panels, particularly the GEM-P9600, GEM-P1632, and GEM-P816, exemplify this commitment to excellence in security technology. These panels are designed to meet the diverse needs of residential and commercial properties, offering a combination of reliability, functionality, and user-friendly features.

Starting with the GEM-P9600, this control panel serves as a central hub for monitoring and controlling various security devices. One of its standout features is its ability to support up to 96 zones, making it suitable for larger installations. Its versatile communication capabilities include options for TCP/IP, cellular, and telephone dialer systems, ensuring that users can stay connected regardless of their circumstances. The panel also integrates seamlessly with Napco's range of peripheral devices, including motion detectors, door/window contacts, and glass break sensors, enhancing the overall security ecosystem.

The GEM-P1632 is tailored for medium-sized applications, supporting up to 32 zones. Its user-friendly interface includes an LCD keypad that provides live feedback and allows for easy programming. Just like the GEM-P9600, it supports multiple communication methods, which facilitate real-time alerts and remote management through mobile devices or web applications. The GEM-P1632 also features an advanced event logging system, offering comprehensive records of system activity, which is invaluable for both security professionals and end-users.

In contrast, the GEM-P816 is designed for smaller setups, accommodating up to 16 zones. Despite its compact nature, it boasts many of the same powerful features as its larger counterparts, including compatibility with various communication technologies and integration with smart home systems. Users appreciate its simplified programming, which allows for quick installation and setup. Additionally, with the GEM-P816, end-users have the option to add wireless capabilities, providing flexibility in choosing security devices based on their unique needs.

All three panels utilize advanced technologies, including robust encryption protocols for secure communication and intuitive user interfaces that simplify operation. The GEM series is built with scalability in mind, allowing users to expand their systems effortlessly as their security needs evolve. With a strong emphasis on performance and reliability, Napco's GEM-P9600, GEM-P1632, and GEM-P816 control panels are ideal solutions for anyone looking to enhance the security of their homes or businesses.