Programming the GEM-P816 & GEM-P1632

Programming the GEM-P816 & GEM-P1632

01

INTERIOR

BYPASS

FIRE/TBL SYS TBL

CHIME

INTERIOR BYPASS

FIRE/TBL SYS TBL

CHIME

(Direct Entry)

Total Number of Zones in Area 1 (Appears for New Panel Only)

Press the Abutton and then directly enter the total number of zones to be

programmed for Area 1. Valid entries are from 01 to 32. Directly enter the total number of zones, including leading zeros. Use number buttons 1through

9. NOTE: Press the 0 button for a zero. The system is based on

groups of 4 zones each (after the first 8 zones), and will automatically round up to the next group of 4. For example, if you enter 18, it will automatically

convert this to 20 zones. Press Jto save. Press NEXT (E) button to

proceed. NOTE: If you are programming a 2 Area system, enter the total number of zones required for Areas 1 & 2. The Direct Address Program Mode can then be used to remove zones from Area 1 and place them in Area 2. See Zone Options. If Programming a Wireless Only system, or using wireless only on Zones 9-32, enter the total number of zones in system. Enter the transmitter points in the RF Transmitter section of the Easy Menu Driven Programming Mode.

03

INTERIOR

BYPASS

FIRE/TBL SYS TBL

CHIME

 

INTERIOR BYPASS

FIRE/TBL SYS TBL

CHIME

(Press YES or NO)

Panel Zone Doubling?(Appears for New Panel Only) (GEM-P1632 only)

Press the Abutton. If the total number of zones in Area 1 entered was 16 or greater, press YES (E) to effectively double the capacity of the control

panel's hard wired zones from 8 to 16. The 16 zones will no longer be EOL zones, but will be designated for Normally Closed devices only. The terminal for Zone 1 will now support Zones 1 and 9 with the use of the supplied EZ Zone DoublingTM resistors, E & Z supplied. (Refer to Wiring Diagram and Installation Instructions). If Panel Zone doubling is not desired, press NO (E). NOTE: Answer NO for GEM-P816

04

INTERIOR

BYPASS

FIRE/TBL SYS TBL

CHIME

 

INTERIOR BYPASS FIRE/TBL SYS TBL CHIME

(Press YES or NO)

05

INTERIOR

BYPASS

FIRE/TBL

SYS TBL

CHIME

 

 

INTERIOR

BYPASS

FIRE/TBL

SYS TBL

CHIME

(Press YES or NO)

Fire Zones in Area 1 (Appears for New Panel Only) Press the A

button and then directly enter the zone number of any zones which are to be used as Fire Zones (both 2-wire, 4-wire or wireless). Valid entries are from 01 to 32. Directly enter each zone number, including leading zeros, and press

Jto save, and then repeat for any additional zone(s). Press NEXT (E)

button to proceed.

2-Wire Fire Zones in Area 1 (Appears for New Panel Only) Press the Abutton and then directly enter the zone number of any Fire Zones (from

previous question) which are to be used with 2-wire smoke detectors. The only valid entries are 07 and 08. Directly enter each zone number, including

leading zeros. Press Jto save and then repeat for any additional zone(s).

NOTE: Only zones which have been designated as Fire Zones may be pro- grammed as 2 Wire Fire zones. Press NEXT (E) button to proceed.

NOTE: JP3 must be set to “2-WF” position for 2-wire fire zones for zones 7 and 8 (refer to Installation Instructions).

GEMINI

 

 

 

 

 

 

 

 

 

 

 

ENT INTERIOR

BYPASS

FIRE/TBL

SYS TBL

CHIME

06 NEXT/YES

 

 

 

 

A

1

2

3

E

 

 

 

 

D PRIOR/NO

 

 

 

 

B

4

5

6

F

 

 

 

 

AREA

 

 

 

 

C

7

8

9

0 G

 

 

 

 

COMPUTERIZED SECURITY SYSTEM

 

 

 

 

 

 

 

 

INTERIOR

BYPASS

FIRE/TBL

SYS TBL

CHIME

(Yes or No)

Report all Zones to Central Station?(Appears for New Panel Only)

Press YES (E) button for all zones to report to central station; press NO (F) button for no zones to report (LOCAL SYSTEM).