CARE OF GLASS, ENAMELLED AND PLATED PARTS
W415-0171/D/01.06.04

5

CARE OF GLASS, ENAMELLED AND PLATED PARTS

Do not use abrasive cleaners to clean these parts. Buff lightly with a clean dry cloth. Porcelain enamelled compo- nents must be handled with care. The baked-on finish is glasslike. If struck, it will chip! Touch-up paint is available through your Napoleon dealer.

The glass is 3/16" ceramic glass available from your Na- poleon dealer. DO NOT SUBSTITUTE MATERIALS. Clean the glass after the first 10 hours of operation with a recom- mended gas fireplace glass cleaner. Thereafter clean as required. DO NOT CLEAN GLASS WHEN HOT! If the glass is not kept clean permanent discolouration and / or blem- ishes may result.

INSTALLATION

FIGURE2

Clean out the ashes from the inside of the woodburning fireplace. Make sure that the chimney and woodburning fireplace are in clean and sound condition. Do not remove bricks or mortar from the masonry fireplace. If necessary have any repair work done by a qualified person before installing the insert. Remove the existing fireplace damper or lock into an open position. Line the chimney with a 4 inch diameter approved liner. Pack insulation around the liner in the damper area to prevent air flow from entering the chimney. Chimney installation must conform to both national and local code requirements. The liner must be continuous from the fireplace to the chimney cap.

FIGURE3

Remove the securing screw from the front of the dilution plate. Push the dilution hood out of its securing clip and attach the liner using 3 screws equally spaced. Move the insert into the centre of the woodburning fireplace making sure that the dilution draft hood inserts back into its secur- ing clip. Level using the four levelling screws located front and back on either side of the fireplace base.

FIGURE4

Levelling the insert will eliminate rocking or excessive noise when the fan is in operation. Replace the securing screw to the front of the dilution plate.

FIGURE5

Install rigid black pipe, a flex connector, if local codes per- mit, or 1/2" type L, copper tubing with a 3/8" to 1/2" adapter and a shut off valve to the fireplace. Seal and tighten se- curely. The adapter will be required between the gas valve and the copper tubing or flex connector.

Do not damage or kink flex connector!

Check for gas leaks by brushing on a soap and water solution.

Do not use open flame!

An on/off switch has been included and can be located at the lower right, behind the louvre access door or at the right side trim.

For ease of accessibility, this switch may be replaced with a wall switch or substituted with a millivolt thermostat that may be installed in a convenient location on any wall. Route 2-strand (solid core) millivolt wire through the electrical hole located at the bottom right side of the unit. The rec- ommended maximum lead length depends on wire size:

WIRE SIZE
MAX. LENGTH

14gauge

100 feet

16gauge

60 feet

18gauge

40 feet

1

2

3

FIGURE6

Attach the two leads to terminals 1 and 3 located on the gas valve.

Do not connect either the wall switch or the gas valve to electricity (110 volts or 24 volts).