Napoleon Fireplaces GI3016-P, GI3016-N Blower Replacement Installation, Adjustments, Maintenance

Models: GI3016-N

1 16
Download 16 pages 24.61 Kb
Page 11
Image 11
MAINTENANCE

11

MAINTENANCE

TURN OFF THE GAS AND ELECTRICAL POWER

BEFORE SERVICING THE FIREPLACE.

CAUTION: Label all wires prior to disconnection when serv- icing controls. Wiring errors can cause improper and dan- gerous operation. Verify proper operation after servicing. This insert and its venting system should be inspected before use and at least annually by a qualified service per- son. The fireplace area must be kept clear and free of combustible materials, gasoline or other flammable va- pours and liquids. The flow of combustion and ventilation air must not be obstructed.

1.In order to properly clean the burner and pilot assembly, remove the logs to expose both assemblies.

2.Keep the control compartment, logs, burner, air shutter opening and the area surrounding the logs clean by vacu- uming or brushing, at least once a year.

3.Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or are not burn- ing properly. (right brick panel must be removed in order to facilitate burner removal)

4.Check to see that the pilot flame is large enough to engulf the thermopile on one leg and reaches toward the burner on the other leg.

5.Replace the cleaned logs.

6.Check to see that the main burner ignites completely on all openings when the gas knob for the burner is turned on. A 5 to 10 second total light-up period is satisfactory. If ignition takes longer, consult your Napoleon dealer / dis- tributor.

7.Check that the gasketing on the door is not broken or missing. Replace if necessary.

BLOWER REPLACEMENT INSTALLATION

BLOWER SYSTEM

The Napoleon gas fireplace insert comes standard with a blower, a heat sensor, variable on/off speed control and a power cord. Because the blower is thermally activated, when turned on, it will automatically start approximately 15 minutes after lighting the fireplace and will run for approxi- mately 30 minutes after the fireplace has been turned off. Use of the fan increases the output of heat. Air, drawn in through the lower louvre access door, is driven up the back of the firebox, and exhausted as hot air between the upper louvres.

FIGURE 21

BLOWER REPLACEMENT INSTRUCTIONS

Turn off the gas and electric power to the unit.

Remove the glass door.

Remove the lower glass bracket.

Remove the logs.

Remove the burner assembly. (right brick panel must be removed in order to facilitate removal)

Remove the four screws holding the access door in place on the control assembly (located to the back of the burner assembly.) For location, see picture in re- placement parts.

Disconnect the electrical connectors at the blower.

Remove the blower.

Drywall dust will penetrate into blower bearings causing irrepairable damage and must be prevented from coming into contact with the blower or its compartment.

Any damage resulting from this condition is not covered by the warranty policy.

ADJUSTMENTS

VENTURI ADJUSTMENT

Natural gas models have air shutters set at 1/16 (.063") inch open. Propane gas models have air shutters set at [5/ 16] (.313) inch open. Closing the air shutter will cause a more yellow flame, but can lead to carboning. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports. The flame may not ap- pear yellow immediately; allow 15 to 30 minutes for the final flame colour to be established.

AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY AQUALIFIED GAS INSTALLER!

FIGURE 23

PILOT BURNER ADJUSTMENT

1.Remove the pilot adjustment cap.

2.Adjust the pilot screw to provide properly sized flame.

3. Replace the pilot adjustment cap.

THERMOPILE

FIGURE 24

PILOT ADJUSTMENT

CAP PILOT ASSEMBLY

FIGURE 25

FLAME MUST ENVELOP UPPER 3/16" TO ½" OF THERMOPILE

W415-0171/D/01.06.04

Page 11
Image 11
Napoleon Fireplaces GI3016-P Blower Replacement Installation, Adjustments, Maintenance, Blower System, Venturi Adjustment