ELECTRICAL CONNECTION

6

ELECTRICAL CONNECTION

!WARNING

RISK OF ELECTRIC SHOCK!

Control and valve operate with 110v.

Do NOT use the appliance if any part has been under water. Call a qualified service technician IMMEDIATELY to have the appliance inspected for damage to the electrical circuit.

HARD WIRING CONNECTION

IT IS NECESSARY TO HARD WIRE THIS

APPLIANCE.

This appliance must be electrically connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the ANSI/NFPA 70-1996 NATIONAL ELECTRICAL CODE in the United States.

NOTE: During assembly, anti-oxidant compound was applied to all electrical connections. If replacing the existing wire harness or disconnecting any connectors, it is highly recommended to re-apply anti-oxidant compound to the relative connections.

FIGURE 3

 

GAS

 

 

 

 

 

 

 

 

 

 

VALVE

 

 

IGNITOR

 

 

 

 

 

IGNITOR

 

 

1

2

3 4

WIRE

 

 

 

 

 

 

 

BROWN

 

 

 

 

 

B

 

 

 

 

 

L

 

 

CONTROL MODULE

G

 

A

 

 

 

C

 

 

R

W

 

SWITCH

 

O

K

 

 

H

 

 

 

U

I

 

 

 

Illustration for reference only.

N

T

 

 

 

D

E

 

 

 

Follow the complete installation

 

 

 

 

 

instructions included with the GFI.

 

 

 

 

 

110v

 

 

 

 

 

POWER

 

 

RESET TEST

 

 

SUPPLY

GFI

 

 

 

 

(Ground Fault Interrupter)

 

 

 

 

CLEARANCES TO COMBUSTIBLES

!WARNING

The GSST8 is designed for outdoor application only. The unit must be installed in the cabinet provided. The cabinet is designed to be installed on finished surfaces.

The GSST8 can be recessed into a structure a maximum of 12” provided that all clearances are maintained.

The GSST8 cabinet may be installed directly onto a combustible surface.

COMBUSTION AND VENTILLATION

AIR

This fireplace is intended for installation on an outdoor patio or in your yard. It must never be installed inside the warm air envelope of your structure.

It is highly recommended that this fireplaces be installed in a “sheltered” area. Direct wind will cause an erratic flame and possible pilot or main burner outage.

An erratic flame could also lead to excessive carboning (black soot), this condition is not a safety issue but is visually undesirable.

Typical installation may include covered patio, screened porch, gazebo, or on an outside wall of a house.

MINIMUM CLEARANCES TO

 

 

 

 

FIGURE 4

COMBUSTIBLES:

 

 

 

 

 

 

 

 

-

18” to top

VENTILLATED

-

1” to sides

SOFFIT

 

 

 

 

 

 

 

 

-

8” to bottom

 

 

 

 

 

 

24”

 

 

 

 

 

 

 

 

-

0” to rear

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAX.

 

 

 

 

 

 

 

 

 

 

 

 

 

18”

 

 

 

 

 

 

MIN.

 

OUTDOOR

8”

MIN.

NOTE: Ensure the area has adequate ventilation.