2
TABLE of CONTENTS
PG | INTRODUCTION | 12 | OPERATING INSTRUCTIONS |
| Warranty | 13 | MAINTENANCE |
| General Instructions | ||
| General Information / Rates and Efficiencies |
| Cleaning |
| Care of Glass and Plated Parts | 13 | ADJUSTMENTS |
| Dimensions | ||
INSTALLATION |
| Gas Pressure Adjustment | |
| Venturi Adjustment | ||
| Gas Installation |
| Flame Characteristics |
| Electrical Connection |
| |
| 14 | REPLACEMENTS | |
| Clearance to Combustibles | ||
FINISHING |
| Replacement Parts | |
| Accessories | ||
| TMCSS Mounting Cabinet Installation | 15 | TROUBLE SHOOTING GUIDE |
| Door Removal | ||
| Rain Tabs |
|
|
| Glass Removal | 16 | SERVICE HISTORY |
| TFSSO Frame Installation |
Logo Placement
Accent Glass Installation
LK8 Light Installation (Optional)
!WARNING
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Read the installation, operating, and maintenance instructions thoroughly before installing or servicing this equipment.
!WARNING
•Do not burn wood or other materials in this enclosure.
•Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Supervise young children when they are in the same area as the enclosure.
•Clothing or other flammable material should not be placed on or near the enclosure.
•Due to high temperatures, the enclosure should be located out of traffic.
•Ensure you have incorporated adequate safety measure to protect infants/toddlers from touching hot surfaces.
•Even after the appliance is out, the glass and/or screen will remain hot for an extended period of time.
•Check with your local hearth specialty dealer for safety screens and hearth guards to protect children from hot surfaces.
•Any safety screen or guard removed for servicing must be replaced prior to operating the enclosure.
•It is imperative that the control compartments, burners and circulating blower and its passageway in the enclosure is kept clean. The appliance should be inspected before use and at least annually by a qualified service person. The enclosure area must be kept clear and free from combustible materials, gasoline and other flammable
vapours and liquids.
•Under no circumstances should this enclosure be modified.
•Do not use this enclosure if any part has been under water. Immediately call a qualified service technician to inspect the enclosure and to replace any part of the control system and any gas control which has been under water.
•Do not operate the appliance with cracked or broken glass. Replacement of the glass should be done by a licensed or qualified service person.
•Do not strike or slam shut the enclosure glass doors.
•Provide adequate ventilation and combustion air. Refer to unvented room heaters installation instructions. Never obstruct the front opening of the enclosure.
•Furniture or other objects must be kept a minimum of 4 feet away from the front of the enclosure.
•Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this enclosure.
•This appliance is only for use with the type of gas indicated on the rating plate.
•The gas log heater must be secured to the enclosure floor to ensure that the position is not changed while adjusting controls.
•Only doors / optional fronts certified with the unit are to be installed on the appliance.
•This enclosure uses and requires a fast acting thermocouple. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.
•The burner must be replaced prior to the appliance being put into operation if it is evident the burner is damaged. Replace only with a burner supplied by Wolf Steel Ltd.
NOTE: Changes, other than editorial, are denoted by a line in the margin.