ELONGATED SLOTS

20

OPTIONAL BLOWER INSTALLATION

 

d

b

re

l

 

a

 

c

 

k

 

 

white

FIGURE 40

INSTALLATION TO BE DONE BY A QUALIFIED IN- STALLER and must be electrically connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States

If the fireplace was not previously equipped with a blower: route a grounded 2-wire, 60hz power cable to the receptacle / junction box. At this point, it must be strain

Attach the connectors from the black and white wires to the thermodisc and se- cure the thermodisc bracket to the securing stud at the bottom left of the unit using a lock washer and wing nut. En- sure that the thermodisc touches the firebox wall.

Attach the connectors from the black and red wires to the blower.

Attach and secure the vari- able speed switch using the nut provided. Plug the harness cord into the re- ceptacle.

THERMODISC

RECEPTACLE /

JUNCTION BOX

GROUND

SCREW

FIGURE 44

FIGURE 45

relieved and insulated.

The three slots on the

blower mounting bracket allow ease of

adjustment when attaching the blower. For a quiet running blower, do not allow the

assembly to sit on the

FIGURE 41

firebox base.

 

Slide the vibration reducing pad (A) into the clip (C) and up against the threaded stud (B) at the other end. The blower must be able to be positioned entirely onto the pad.

Tilt the blower onto its side. Slide it past the controls and into the clip (C). Secure to the threaded stud using the lock washer and wing nut provided. Ensure that the blower does not touch the fireplace base or the firebox.

The wire harness provided in this kit is a universal harness. When installed, ensure that any excess wire is contained, preventing it from making con- tact with moving or hot objects.

Because the blower is thermally activated, when turned on, it will automatically start approximately 10 minutes after lighting the fireplace and will run for approximately 30-45 minutes after the fireplace has been turned off. Use of the fan increases the output of heat.

Drywall dust will penetrate into the blower bear- ings, causing irreparable damage. Care must be taken to prevent drywall dust from coming into contact with the blower or its compartment. Any damage resulting from this condition is not cov- ered by the warranty policy.

B

AC

FIGURE 42

FIGURE 43

W415-0244 / A / 05.15.03

Page 20
Image 20