VENTING APPLICATION FLOW CHART

HORIZONTAL TERMINATION

VERTICAL

TERMINATION

vertical rise is equal to or greater than the horizontal run

horizontal run + verti- cal rise to m a x i m u m of 40 feet

vertical rise is less than horizontal run

horizontal run + verti- cal rise to maximum of 24.75 feet

4.2times the vertical rise equal to or greater than the horizontal run

vertical rise is equal to or greater than the horizontal run

horizontal run + verti- cal rise to m a x i m u m of 40 feet

v e r t i c a l rise is less than hori- zontal run

horizontal run + verti- cal rise to m a x i m u m of 40 feet

3 times the vertical rise equal to or g r e a t e r than the horizontal run