Chapter4 Programmingwith NI-IMAQ for 1394 VIs
©NationalInstruments Corporation 4-9 NI-IMAQfor IEEE-1394 Cameras User Manual
animage acquired using IMAQ1394 Snap. You can display images in the
sameway using any acquisition type. For more informat ion on the display
capabilities of IMAQVision, consult the IMAQ Vision for LabVIEW
UserMan ual.
Figure4-8. Displayingan Image Using IMAQ WindDraw
Ifyou do not have IMAQ Vision, you can display an imageon a
LabVIEW Intensity Graph for 8-bit and 16-bit monochrome images or on
ap icture control for RGB images.
Beforeyou can properly display an image onan Intensity Graph, you need
to make some minor changes to the default properties of the Intensity
Graph.Perform th efoll owingsteps to modify the properties:
1. Placethe Intensity Graph o n the front panel, pop up on the graph, and
choose TransposeArray.
2. Createthe correct grayscale color palette by popping up on the marker
labeled 50 on the color ramp and choosing Delete Marker.Also,
changethe maximum value on the color palette from 100 to the
maximump ixelvalue in your image255 for 8-bit im ages,1 ,023 for
10-biti mages, and 4,095 for 12-bit images.
3. Invertthe y-axis. You might also need to change the ranges of the
x-and y-axes to match the width and height of the image.