Chapter4 Programmingwith NI-IMAQ for 1394 VIs
NI-IMAQfor IEEE-1394 Cameras User Manual 4-12 ni.com
Error HandlingEvery NI-IMAQ for 1394 VI contains an error in input cluster and an
error outout put cluster, as shown in Figure 4-12. The clusters contain a
Boolean value that indicates whether an error occurred, the code for the
error,and the source or the name of the VI that returned the error. If error
in indicatesan error,the V I passes the error information to error out and
does not execute any NI-IMAQ for 1394 function.
Figure4-12. Error Clusters
Youcan use the Simple Error Handler VI (FunctionsยปTime&Di alog
palette)to check for errors that occur while executing a VI. If you wire an
error cluster to the Simple ErrorHandler VI, the VI deciphers the error
information and displays a dialog box that describes the error.If no error
occurred,the Simple Error Handler VI does nothing. Figure 4-13shows
howto wire an NI-IMAQ for 1394 Cameras VI to the Simple Error
Handler VI.
Figure4-13. Error Checking using the Simple Error Handler VI