Appendix A Specifications
© National Instruments Corporation A-3 VXI-MXI-Express Series User Manual
Operating Environment
Ambient temperature range....................0 to 55 °C (Tested in accordance
with IEC-60068-2-1 and
IEC-60068-2-2: meets
MIL-PRF-28800F Class 3 low
temperature limit and
MIL-PRF-28800F Class 2 high
temperature limit.)
Relative humidity range.........................10% to 90% (Tested in
accordance with
IEC-60068-2-56.)
Storage Environment
Ambient temperature range....................–40 to 85 °C (Tested in
accordance with IEC-60068-2-1
and IEC-60068-2-2; meets
MIL-PRF-28800F Class 3 limits.)
Relative humidity range......................... 5% to 95% (Tested in accordance
with IEC-60068-2-56.)
EMI........................................................ FCC Class A verified, EC verified
Shock and Vibration
Operational shock.................................. 30 g peak, half-sine, 11 ms pulse
(Tested in accordance with
IEC-60068-2-27; meets
MIL-PRF-28800F Class 2 limits.)
Random vibration
Operating........................................ 5 to 500 Hz, 0.3 grms
Nonoperating.................................. 5 to 500 Hz, 2.4 grms
(Tested in accordance with
IEC-60068-2-64. Nonoperating
test profile exceeds the
requirements of
MIL-PRF-28800F, Class 3.)