Glossary
VXI-MXI-Express Series User Manual Glossary-6 ni.com
KK kilo—the prefix for 1,024, or 210, used with B (byte) in quantifying data or
computer memory.
k kilo—the standard metric prefix for 1,000, or 103, used with units of
measure such as volts, hertz, and meters.
Llogical address An 8-bit number that uniquely identifies each VXIbus device in a system.
It defines the A16 register address of a device, and indicates Commander
and Servant relationships.
Mm meters
M mega—(1) the standard metric prefix for 1 million or 106, when used with
units of measure such as volts and hertz; (2) the prefix for 1,048,576, or 220,
when used with B (byte) to quantify data or computer memory.
master A functional part of a VME/VXIbus device that initiates data transfers on
the backplane. A transfer can be either a read or a write.
message-based
device
An intelligent device that implements the defined VXIbus registers and
communication protocols. These devices are able to use Word Serial
Protocol to communicate with one another through communication
registers.
MODID Module ID lines—used in VXI to geographically locate boards and to
dynamically configure boards.
MTBF Mean Time Between Failure
MXI-3 A PCI Master/Slave system implementing the PCI-to-PCI Bridge register
set. It couples two physically separate PCI buses with either a copper or
fiber optic data link capable of 1.5 Gbits/s serial data rates.
MXI-Express An extension of MXI based upon PCI Express. MXI-Express provides
bandwidth of up to 110 MB/s.