Event | Message |
|
|
| Action | ||
ID |
|
|
| ||||
|
|
|
|
|
| ||
6684 | Physical | Disk | is marked | as | DEAD | Replace the failed HDD. | |
due to PFA condition of the disk |
| ||||||
|
| ||||||
6685 | Physical | Disk | is marked | as | DEAD | Replace the failed HDD. | |
due to forced offline state |
|
|
| ||||
|
|
|
| ||||
| RAID | migration |
| has | Physical disk error detected. If it cannot be fixed, replace | ||
6149 | encountered | a physical | disk | the HDD. | |||
| error |
|
|
|
|
| |
| RAID | migration |
| has | Migration aborted. Please contact the sales representative | ||
6150 | encountered | a physical | disk | for reconstruction of the array. | |||
| error |
|
|
|
|
| |
6154 | Array | was | made Incomplete | An error occurs during Migration. Please contact the sales | |||
due to missing NV Watermark | representative for reconstruction of the array. | ||||||
| |||||||
7681 | Rebuild is completed |
|
| Rebuild is completed. Check the status of the logical drive. | |||
|
|
| |||||
|
|
|
|
|
|
| |
7682 | Rebuild is paused |
|
| Rebuild is stopped. Restart rebuilding as soon as possible. | |||
|
|
| |||||
|
|
|
|
|
|
| |
7683 | Rebuild is resumed |
|
| No specific action required. | |||
|
|
| |||||
|
|
|
|
|
|
| |
7684 | Rebuild is stopped |
|
| Rebuild is stopped. Restart rebuilding as soon as possible. | |||
|
|
| |||||
|
|
| |||||
7687 | Rebuild is aborted due to an | Rebuilding aborted. Please contact the sales representative. | |||||
internal error |
|
|
| ||||
|
|
|
| ||||
7689 | Rebuild is queued |
|
| No specific action required. | |||
|
|
| |||||
|
|
|
|
|
|
| |
7696 | Auto rebuild can not start | The capacity of unconfigured physical drive is not capable | |||||
of rebuild. Replace a drive with proper capacity. | |||||||
|
|
|
|
|
| ||
7697 | Rebuild stopped internally | Rebuilding aborted. Please contact the sales representative. | |||||
| |||||||
|
|
| |||||
1542 | Redundancy check is aborted | Check HDD and cables and replace it if any failure exists. | |||||
due to an internal error |
|
| |||||
|
|
| |||||
| Redundancy |
| check | If any error occurs in HDD, replace that HDD. If no error | |||
1543 | encountered | inconsistent | occurs in HDDs, back up the system data and replace all | ||||
| block(s) |
|
|
| the HDDs. | ||
1546 | Redundancy | check | task is | Check HDD and cables and replace it if any failure exists. | |||
stopped internally |
|
|
| ||||
|
|
|
| ||||
8192 | SMART error is received |
|
| Replace the failed HDD. | |||
|
|
| |||||
|
|
|
|
|
|
|
The above table shows the event IDs in decimal. The events listed in the table are reported to NEC ESMPRO Manager. The symbols such as %1 in messages are padding characters.
- 78 -