Event

Message

 

 

 

Action

ID

 

 

 

 

 

 

 

 

 

6684

Physical

Disk

is marked

as

DEAD

Replace the failed HDD.

due to PFA condition of the disk

 

 

 

6685

Physical

Disk

is marked

as

DEAD

Replace the failed HDD.

due to forced offline state

 

 

 

 

 

 

 

 

RAID

migration

 

has

Physical disk error detected. If it cannot be fixed, replace

6149

encountered

a physical

disk

the HDD.

 

error

 

 

 

 

 

 

RAID

migration

 

has

Migration aborted. Please contact the sales representative

6150

encountered

a physical

disk

for reconstruction of the array.

 

error

 

 

 

 

 

6154

Array

was

made Incomplete

An error occurs during Migration. Please contact the sales

due to missing NV Watermark

representative for reconstruction of the array.

 

7681

Rebuild is completed

 

 

Rebuild is completed. Check the status of the logical drive.

 

 

 

 

 

 

 

 

 

 

7682

Rebuild is paused

 

 

Rebuild is stopped. Restart rebuilding as soon as possible.

 

 

 

 

 

 

 

 

 

 

7683

Rebuild is resumed

 

 

No specific action required.

 

 

 

 

 

 

 

 

 

 

7684

Rebuild is stopped

 

 

Rebuild is stopped. Restart rebuilding as soon as possible.

 

 

 

 

 

 

7687

Rebuild is aborted due to an

Rebuilding aborted. Please contact the sales representative.

internal error

 

 

 

 

 

 

 

7689

Rebuild is queued

 

 

No specific action required.

 

 

 

 

 

 

 

 

 

 

7696

Auto rebuild can not start

The capacity of unconfigured physical drive is not capable

of rebuild. Replace a drive with proper capacity.

 

 

 

 

 

 

7697

Rebuild stopped internally

Rebuilding aborted. Please contact the sales representative.

 

 

 

 

1542

Redundancy check is aborted

Check HDD and cables and replace it if any failure exists.

due to an internal error

 

 

 

 

 

 

Redundancy

 

check

If any error occurs in HDD, replace that HDD. If no error

1543

encountered

inconsistent

occurs in HDDs, back up the system data and replace all

 

block(s)

 

 

 

the HDDs.

1546

Redundancy

check

task is

Check HDD and cables and replace it if any failure exists.

stopped internally

 

 

 

 

 

 

 

8192

SMART error is received

 

 

Replace the failed HDD.

 

 

 

 

 

 

 

 

 

 

The above table shows the event IDs in decimal. The events listed in the table are reported to NEC ESMPRO Manager. The symbols such as %1 in messages are padding characters.

- 78 -