After the installation of WebPAM PRO, the following messages registered with the name "Promise Event Logger" are set as reported sources. To change the setting, redefine it by using the report setting feature of the NEC ESMPRO Agent.
Event | Message |
|
|
|
|
|
| Action |
|
|
|
|
|
| |||
ID |
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
512 | Battery | temperature | is | above | No action required if the ID 517 message has not been | ||||||||||||
the threshold |
|
|
|
| registered within 8 hours. If there is no ID 517 message, | ||||||||||||
|
|
|
|
| the battery is required to be replaced. |
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
517 | Battery is charging |
|
|
| This is for checking the ID 512 message. |
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
| Failure detected in battery. Check the battery and its life | |||||||
526 | Battery is not accessible |
|
|
| duration and replace it if any failure exists or it has little | ||||||||||||
|
|
|
|
|
|
|
|
|
| time left to live. |
|
|
|
|
|
| |
| The write policy of writeback | Check the battery if any failure exists. |
|
|
| ||||||||||||
529 | logical | drive | switched | from |
|
|
|
|
|
|
|
| |||||
| writeback to writethru |
|
|
|
|
|
|
|
|
| |||||||
| The write policy of writeback | Check the battery if any failure exists. |
|
|
| ||||||||||||
530 | logical | drive | switched | from |
|
|
|
|
|
|
|
| |||||
| writethru to writeback |
|
|
|
|
|
|
|
|
| |||||||
| Logical drive initialization marks the | An array became offline. Please replace the failed HDD | |||||||||||||||
4101 | and | contact | the | customer | or | sales | engineer | for | |||||||||
| logical drive offline |
|
|
| reconstruction.. |
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| Logical Drive Initialization is | Check HDD and cables and replace it if any failure exists. | |||||||||||||||
4102 | aborted due to an internal |
|
|
|
|
|
|
|
| ||||||||
| error |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4108 | Quick | Logical |
| drive | initialization | An array became offline. Please replace the failed HDD | |||||||||||
marks the logical drive offline |
| and contact your customer engineer for reconstruction.. |
| ||||||||||||||
|
|
| |||||||||||||||
| Quick |
|
| Logical |
|
| Drive | Check HDD and cables and replace it if any failure exists. | |||||||||
4109 | Initialization is aborted due to |
|
|
|
|
|
|
|
| ||||||||
| an internal error |
|
|
|
|
|
|
|
|
|
|
| |||||
| Logical drive has been placed offline. | An array became offline. Please replace the failed HDD | |||||||||||||||
4611 | and | contact | the | customer | or | sales | engineer | for | |||||||||
| Possible Data Loss |
|
|
| reconstruction. |
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| Physical drive became critical. Please replace the failed | |||||||
4612 | Logical drive has been set to critical | HDD and execute rebuilding. If array has | |||||||||||||||
|
|
|
|
|
|
|
|
|
| rebuilding will be executed automatically. |
|
| |||||
5638 | Media Patrol is aborted due to | Check HDD and cables and replace it if any failure exists. | |||||||||||||||
an internal error |
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
| ||||||
6658 | Physical Disk is marked as DEAD | Replace the failed HDD. |
|
|
|
| |||||||||||
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
| |||||||
6659 | Physical Disk has been reset | Check HDD and cables and replace it if any failure exists. | |||||||||||||||
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
| ||||||||||||
6667 | Physical | Disk | has | been | Physical driver has been removed. Check HDD and cables | ||||||||||||
removed |
|
|
|
|
|
| and replace it if any failure exists. |
|
|
| |||||||
|
|
|
|
|
|
|
|
|
| ||||||||
6671 | Bad | sector |
| is | found on | Replace the HDD with bad sectors. |
|
|
| ||||||||
physical disk |
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
6675 | Previously | configured | disk | is no | Replace the failed HDD. |
|
|
|
| ||||||||
longer found |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
6677 | A physical disk has encountered PFA | Replace the failed HDD. |
|
|
|
| |||||||||||
condition |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
6682 | Physical | Disk | is | marked | as | DEAD | Replace the failed HDD. |
|
|
|
| ||||||
due to removal |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
6683 | Physical | Disk | is | marked | as | DEAD | Replace the failed HDD. |
|
|
|
| ||||||
due to the failure of Reassign |
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
- 77 -