Appendix B Configuration Setting Command
6
chgscsivalidaddress, and delscsivalidaddress options is
invalid.
-number option: Specifies the target Service Processor number.
-scsiguardinvalid option: Determines whether to validate/invalidate the limit for
access from monitoring servers connected through
Ether. If “off” is specified, the limit for access from
monitoring servers becomes valid, and only
monitoring servers at registered IP Addresses are
permitted to make access. If “on” is specified, the
limit for access from monitoring servers becomes
invalid, and monitoring servers at any IP Addresses
are permitted to make access. Therefore, be careful
in specifying “on” for this option.
-specialfile option: Specifies the special file name of the target disk array.
The special file name is displayed by the “volume list
command”. For details on the command, refer to the
“volume list command” explained in the “User’s
Manual” or “User’s Manual (UNIX)” in accordance
with the OS in use.
-subnetmask option: Sets a Subnet Mask. Specify the Subnet Mask in the
input format of “aaa.bbb.ccc.ddd” (in decimal). The
subnet of the disk array’s IP Address is set by
specifying this option.
-view option: Displays Service Processor information. If a Service
Processor number is specified in the “number” option,
the information of only the specified Service Processor
is displayed. If the “number” option is omitted, the
information of all the Service Processors is displayed.
(3) Termination of the iSMnetconf command
When the iSMnetconf command terminates normally, a message is displayed indicating
successful operation if a setting option is specified. If a reference option is specified, the item
for the option is displayed.