Installation instructions
Location for Installing Indoor Unit
Where there is no obstacle near the air outlet and air can be easily blown to every corner.
Where piping and wall hole can be easily arranged.
Keep the required space from the unit to the ceiling and wall according to the installation diagram on previous page.
Where the air filter can be easily removed.
Keep the unit and remote controller 1m or more apart from television, radio etc.
To prevent the effects of a fluorescent lamps, keep as far as possible.
Do not put anything near the air inlet to obstruct it from air absorption.
Where there is strong enough to bear the weight
and is not tend to increase operation noise and vibration.
Location for Installing Outdoor Unit
Where it is convenient to install and well ventilated.
Avoid installing it where flammable gas could leak.
Keep the required distance apart from the wall.
The distance between Indoor and outdoor unit should be 5 meters and can go up to maximum 15 meters with additional refrigerant charge.
Keep the outdoor unit away from a place of greasy dirt, vulcanization gas exit.
Avoid installing it at the roadside where there is a risk of muddy water.
A fixed base where is not subject to increasing operation noise.
Where there is not any blockage for air outlet.
Indoor unit
Pipe length is 15 meters Max.
Outdoor unit
Outdoor unit
Pipe length is 15 meters Max.
Indoor unit
| Max. Allowable Tubing | Limit of Tubing | Limit of Elevation | Required amount of |
Model | Length at Shipment (m) | Length (m) | Difference H (m) | additional refrigerant (g/m) |
|
|
|
|
|
24K | 5 | 15 | 5 | 20 |
|
|
|
|
|