NEC RIH-6867 Installation instructions, Indoorunitinstallation, Installing the Mounting Plate

Models: RIH-6867

1 25
Download 25 pages 20.72 Kb
Page 19
Image 19
Indoorunitinstallation

Installation instructions 1. Installing the Mounting Plate

2. Drill a Hole for Piping3. Indoor Unit Piping InstallationIndoorManual backgroundunitManual backgroundinstallationManual backgroundManual backgroundManual backgroundManual background

1. Installing the Mounting Plate

Decide an installing location for the mounting plate according to the indoor unit location and piping direction.

Manual background Keep the mounting. plate horizontally with a horizontal ruler or dropping line.

Drill holes of 32mm in depth on the wall for fixing the plate.

Insert the plastic plugs to the hole, fix the mounting plate with tapping screws. Inspect if the mounting plate is well fixed. Then drill a hole for piping.

Hook the line here

Line drops from here

Manual backgroundManual backgroundManual background Mounting plate

Dropping line

holes for fixing

Note: The shape of your mounting plate may be different from the one above, but installation method is similar.

2. Drill a Hole for Piping

Wall hole sleeve

Decide the position of hole for piping according to the

( hard polythene tube

location of mounting plate.

prepared by user)

Drill a hole on the wall. The hole should tilt a little

 

downward toward outside.

 

Install a sleeve through the wall hole to keep the wall

5mm

tidy and clean.

(tilt downward)

 

3. Indoor Unit Piping Installation

 

Put the piping (liquid and gas pipe) and cables through the wall hole from outside or put them through

from inside after indoor piping and cables connection complete so as to connect to outdoor unit.

Decide whether saw the unloading piece off in accordance with the piping direction.(as shown below)

Piping direction

 

 

 

 

 

 

trough

 

 

 

 

 

 

 

 

 

 

Unloading

 

 

 

 

 

 

iece

 

4

 

 

 

 

1

3

 

 

 

 

Note: When installing the pipe at the directions

Saw the unloading piece

 

off along the trough

 

1,2 or 4, saw the corresponding unloading piece

2

 

off the indoor unit base.

Manual background After connecting piping as required, install the drain hose. Then connect the power cords. After connecting, wrap the piping, cords and drain hose together with thermal insulation materials.

17

PDF created with pdfFactory Pro trial version www.pdffactory.com