Normal Assignment:

Uplink Assignment:

 

Ports 1–3 on the

Port 4 on the

RJ-45 Connector

Model EN104 hub

Model EN104 hub

Ports 1–7 on the

Port 8 on the

Pin Assignment

Model EN108 hub

Model EN108 hub

 

 

Ports 1–15 on the

Port 16 on the

 

Model EN116 hub

Model EN116 hub

 

 

 

1

Input Receive Data +

Output Transmit Data +

 

 

 

2

Input Receive Data -

Output Transmit Data -

 

 

 

3

Output Transmit Data +

Input Receive Data +

 

 

 

6

Output Transmit Data -

Input Receive Data -

 

 

 

4, 5, 7, 8

Not used

Not used

 

 

 

AUI Connector

The AUI connector for the hub connects the hub through an external transceiver to other devices. An inter-repeater fiber link using a 10BASE-F transceiver is an example of such an application.

AUI connector

1

8

15

9

8148EA

AUI Connector Pin Assignment

Signal

 

 

1, 4, 11, 14, 15

Ground

 

 

2

CI-A

 

 

3

DO-A

 

 

5

DI-A

 

 

6

+ 12 V DC return

 

 

7, 8

Not used

 

 

9

CI-B

 

 

10

DO-B

 

 

12

DI-B

 

 

13

+ 12 V DC (500 mA maximum)

 

 

BNC Connector

The BNC connector for the hub supports 10 Mbps data transmission and connects the hub to other devices.

BNC connector

Center conductor

Ground shield

1

2

 

 

8149EA

Model EN104/EN108/EN116 Ethernet Hub Installation Guide

Page 12
Image 12
NETGEAR EN116, EN104, EN108 manual BNC Connector, AUI Connector Pin Assignment Signal