FS728TP Smart Switch Software User Manual
5-49 Configuring the Device Using Your Browser
v2.0, November 2006
To enable PoE on the device:
1. Click System > PoE Configuration. The PoE Configuration Page opens:
Figure 5-37
The PoE Configuration Page contains the following fields:
Power Status – Indicates the online power source status. The possible field values are:
On – Indicates that the power supply unit is functioning.
Off – Indicates that the power supply unit is not functioning.
Faulty – Indicates that the power supply unit is functioning, but an error has occurred.
For example, a power overload or a short circuit.
Nominal Power – Indicates the actual amount of power the device can supply. The field
value is displayed in Watts.
Consumed Power – Indicates the amount of the power used by the device. The field value
is displayed in Watts.
System Usage Threshold – Indicates the percentage of power consumed before an alarm
is generated. The field value is 1-99 percent. The default is 95 percent.
Trap s – Indicate if PoE device traps are enabled. The possible field values are: