New Buck Corporation manual SECTION INSTALLATION MODEL 34 FP, In Solid Fuel Burning Fireplaces

Models: 34

1 55
Download 55 pages 52.22 Kb
Page 28
Image 28
SECTION III

SECTION III

INSTALLATION MODEL 34 (FP)

IN SOLID FUEL BURNING FIREPLACES

(1)The Model FP-34 may be installed in a masonry fireplace. The minimum fireplace dimension must be 24" high, 29-1/2" wide, and 12" deep.

(2)For minimum dimensions for the sidewall and mantel, see Figure 6.

(3)Center the heater in fireplace opening.

(4)NOTE: See “Producing Adequate Ventilation” page 35.

NOTE: The installer of this appliance must mechanically (peel and stick) attach the marking supplied with this unvented appliance before installing to the inside of the firebox of the solid- fuel burning fireplace or listed ventless firebox enclosure into which the unvented fireplace insert is installed. See the example of the marking on page 10 of this manual.

CAUTION: Cutting any sheet-metal parts of the solid-fuel burning fireplace or listed ventless enclosure in which the unvented fireplace is to be installed is prohibited.

NOTE: “If the factory-built fireplace has no gas access hole(s) provided, an access hole of 1.5 inch (37.5) diameter or less may be drilled through the lower sides or bottom of the firebox in a proper workmanlike manner. This access hole must be plugged with non-combustible insulation after the gas supply line has been installed.”

“Refractory, glass doors, screen rails, screen mesh and solid-fuel log grates (if applicable) can be removed from the fireplace before installing the unvented fireplace insert.”

NOTE: After the unit is positioned in fireplace, mark the trim panels as follows:

A.Set the side panels in place, flat against the fireplace. Mark down the inside edge of the trim panel to make a vertical reference line.

 

CEILING

 

 

 

24"

 

20"

 

7"

7"

 

LEFT

RIGHT

Figure 6

SIDE

SIDE

 

26

 

Page 28
Image 28
New Buck Corporation manual SECTION INSTALLATION MODEL 34 FP, In Solid Fuel Burning Fireplaces, Ceiling, Figure