EQUALIZATION MAIN SELECTION –

16 CHANNEL, FULLY CONFIGURABLE POWER AMPLIFIERS

CONFIGURATION AND SETUP TOOL

EQUALIZATION MAIN SELECTION –

MANUAL EQ SELECTION

Choose the Manual EQ sub-selection and the Manual EQ page is displayed. The amplifier channels are included in a single pull down list along with their names.

Note: If an odd numbered channel is set to 100 watts, it even numbered adjacent channel will not be included in the pull down list (e.g. when channel 15 set to 100 watts, channel 16 will not be included in the pull down list).

1.Choose a channel from the pull down list to adjust its EQ parameters. The current Room EQ Preset is displayed for the selected channel. If any manual adjustments are made and saved, the room preset display changes to “None”.

2.Select or deselect Loudness, Low Cut or High Cut and use the individual arrow buttons to adjust volume, bass, midrange, treble, midrange center frequency and midrange bandwidth for the selected channel.

3.Copy EQ Settings saves all manual EQ parameters for the selected channel to a clipboard including loudness, low cut, high cut, volume, bass, midrange, treble, midrange center frequency and midrange bandwidth.

4.Paste EQ Settings applies the saved clipboard settings to any other selected channel.

5.Set Flat sets the selected channel to the default Flat Room EQ Preset and volume at 0dB.

6.Select Save to save

Manual EQ settings to the amplifier’s memory.