16 CHANNEL, FULLY CONFIGURABLE POWER AMPLIFIERS

TROUBLE-SHOOTING GUIDE

Symptom

Possible Causes and Test Procedure

Sound is distorted on one or all of the channels at normal volumes

Check your configuration worksheet and verify all settings.

Normal volume cannot

One of the internal amplifier fuses is blown. (Return the amplifier to your dealer for service).

be reached

 

Bass sound is weak

Check that the bridging switch is “Off”. If two adjacent channels are connected normally but

the bridging switch is set to the “Bridged” position, the two speakers will play out of phase

and the stereo image is

with each other.

“phasey” sounding in

 

one room

The loudspeakers are wired out of phase. Reverse the connections at the back of one speaker.

 