1 - 10 AMERICAN-LINCOLN TECHNOLOGY

SMART 2000

YOUR SMART 2000 MACHINE HAS BEEN SHIPPED COMPLETE, BUT DO NOT ATTEMPT T O OPERA TE
WITHOUT FOLLOWING THESE INSTRUCTIONS.
PREPARING THE MACHINE FOR OPERATION (IC Engine Powered)
1. Connect and tighten battery cables.
2. Fill the tank with REGULAR GRADE gasoline. (Diesel fuel if equipped with diesel engine.)
WARNING
Never fill the tank while the engine is running. Always be sure the gasoline container and sweeper are electrically
connected before pouring gasoline. This can easily be done by providing an insulated wire (permanently attached
to container) with a battery clip on the other end.
3. Check engine crankcase oil level. Although properly lubricated at the factory, check before starting the
engine. No special break in oil is used and recommended number of operating hours before the initial oil
change is the same as normal. See Maintenance.
4. Check radiator coolant level. Permanent type antifreeze is added at the factory to provide protec-
tion to approximately -35°F (37°C). To retain this protection level, always add ½ part water to ½part
antifreeze.
5. Check oil level in the hydraulic reservoir located at the drivers side of the machine beside the engine. The
oil fill level should be halfway on sight glass. If oil is needed, add Standard, 30 weight, non-detergent motor
oil. After the first 50 operating hours, service must be performed on your engine to ensure future high
performance and trouble free operation. See Maintenance.
MACHINE PREPARATION

Figure 1