C1700

OPERATION OF CONTROLS AND GAUGES

FILTER

SHAKER

SWITCH

C1640-2batt FIGURE 6

CONTROLLER

PUMP MOTOR

PUMP

FIGURE 7

HOPPER

 

SAFETY ARM

 

 

TO

 

ENGAGE

C1700

 

C1700

FIGURE 8

FILTER SHAKER SWITCH (See Figure 6)

The filter shaker switch is located on the instrument panel below the ignition switch. This is a momentary switch that will activate the filter shaker motors for 20 to 30 seconds to clear the dust control filter. The Impeller fan will stop when the filter shaker has been activated. The filter shaker will only operate with the hopper in the “DOWN” position.

Use the filter shaker to clear the filter when the dust control light comes on (warning bank) and just before dumping the hopper.

MillipaK SEM CONTROLLER (See Figure 7)

The controller is located in the seat compartment and includes a number of features designed to help the user track down operational faults, wiring faults or internal controller faults, including a flashing indicator light.

The Flash Codes are:

ON

No fault, normal condition

OFF

Internal controller fault

1 flash

Program Error

2 flashes

High Pedal Disable

3 flashes

MOSFET Short Circuit

4 flashes

Contactor fault or Motor Open Circuit

5 flashes

Not used

6 flashes

Accelerator wire off fault

7 flashes

Low or High battery voltage

8 flashes

Over temperature or timed cutback

HYDRAULIC PUMP (See Figure 7)

The pump is located in the seat compartment and is powered by a 45 amp circuit breaker (on the power panel) and a contact linked with the key switch. It functions at 1450 PSI and features 100 bar relief.

HOPPER SAFETY LOCK ARM (See Figure 8)

The hopper safety arm is located near the right front wheel well. The safety arm will prevent the hopper from dropping unexpectedly during service/maintenance.

TO ENGAGE THE SAFETY ARM:

1.Empty hopper

2.Set the parking brake.

3.Raise the hopper.

4.Lift safety arm to engage the slot on the hopper frame.

5.When work has been completed, return the safey arm to the stowed position.

FIGURE 8 WARNING

When the hopper is raised the safety arm must be engaged

before ANY work is done under the hopper.