OPERATION OF CONTROLS AND GAUGES

 

OPERATION OF CONTROLS AND GAUGES

 

WARNING

 

BANK

CHARGING SYSTEM

RECOVERY

LIGHT

HIGH

 

LIGHT

 

CLOGGED

 

FILTER LIGHT

SOLUTION

HOPPER

LOW LIGHT

TEMP

 

LIGHT

C1636batt

FIGURE 15

WARNING BANK (See Figure 15)

The Warning Bank is located on the instrument panel and provides the operator with fault/status indicators for engine and sweeper systems. The operator should monitor the indicators while sweeping. It is very important that the operator be familiar with the meaning of each indicator.

CHARGING SYSTEM LIGHT

Manual backgroundManual background The charging system light illuminates to indicate a charging system fault. When this occurs the machines charging system is not working properly, have the machine serviced by a qualified Manual background service technician.

CLOGGED FILTER LIGHT (Option)

The clogged filter light illuminates to indicate that the dust control filter is clogged. When this occurs, stop the machine and use the filter shaker to clear the dirt and debris from the filter. After using the filter shaker, continue sweeping.

HOPPER TEMPERATURE LIGHT (Option)

When the temperature of the air moving through the hopper dust control system exceeds 140° F, an automatic protection feature shuts down the dust control fan and illuminates the hopper tem- perature light. When this occurs, shut down the machine and carefully investigate for a possible fire in the hopper, then manually reset the switch.

SOLUTION LOW LIGHT

The solution low warning light will illuminate when the solution tank is empty, indicating the end of the scrubbing cycle.

RECOVERY HIGH LIGHT

The recovery high warning light will illuminate approximately 5 minutes before the recovery tank is Manual background full, giving ample time to complete the scrubbing cycle, before the mechanical float shuts off the

vacuum to the recovery tank.