THE RECOVERY OR ESP AND AUTOFIL SYSTEM - HOW IT WORKS

During the scrubbing process, filtered water from the solution tank is fed to the solution line, where it combines with detergent from the metering pump. This mixture is then fed to the floor where three disc scrubbing brushes work to dislodge soil.

After scrubbing, the dirty solution is vacuumed from the floor and discharged into the recovery tank. At inter- vals, a float switch activates the recycling pump, which sends filtered solution from the recovery tank to the solution tank. Detergent is added continuously to solution water from the flow valve.

The autofil system distributes water from the supply hose into the recovery and solution tanks. Then a solenoid valve is closed when the proper level in the solution tank is reached.

NOTE

Both tanks must be drained and cleaned before filling.

Tuck solution tank drain hose behind bumper during operation hose

 

 

ORIFICE

CHECK

 

VALVE

 

DETERGENT

 

 

TANK

 

 

SOLUTION

SOLUTION

RECOVERY

TANK

PUMP

TANK

 

FILTER

FILTER

 

 

 

FLOW VALVE

AUTOFIL VALVE

 

 

DETERGENT

SEPARATOR

FILL COUPLING

SCRUB

PUMP

 

 

BRUSH

SQUEEGEE

 

 

P4759a

FLOOR CONTACT

 

 

 

P4759A

FIGURE 33

 