MAINTENANCE SCHEDULE

MAINTENANCE SCHEDULE

 

DAILY

CLEAN ALL FILTERS

X

CHECK POWER CORD

X

FLUSH OUT with DESCALER

REPLACE VAC MOTOR BRUSHES

REPLACE PRESSURE REGULATOR REPLACE VAC MOTOR BRUSHES

WEEKLY

MONTHLY

YEARLY

X

X

OTHER

Around 1500 hours

Or as needed Around 1500 hours

TROUBLE SHOOTING:

ALWAYS UNPLUG THE MACHINE BEFORE

 

 

 

DISCONNECTING OR CONNECTING ANY

 

 

 

WIRES OR COMPONENTS.

IF THIS OCCURS

CHECK THIS

 

 

 

Solution tank is empty.

 

 

 

 

 

NO SPRAY

Clogged spray tip.

 

 

Pump not running or not primed.

 

 

 

 

Valve on wand not operating.

 

 

 

 

LOW SUCTION

Debris is plugging cleaning tool or vacuum hose.

 

Drain gate is not completely closed, or seals are damaged.

 

 

Vacuum dome is not seated or is damaged.

 

 

 

 

 

NO SUCTION

No power to motor.

 

 

Test the switch.

 

 

 

 

 

 

Test the vacuum motor.

 

 

 

Test the Vacuum Circuit Board.

 

 

 

 

LOW HEAT

Spraying too long. Try spraying for 10 - 12 seconds, or about three strokes.

 

Heat exchanger needs to be flushed.

 

 

Wrong tool being used. Too much water passing through. Longer hose or larger

 

 

diameter hose, than standard.

 

 

 

 

 

 

Heat is not turned on.

 

 

NO HEAT

No power in the wall outlet - check to see if the breaker has tripped.

 

 

Check to see if the fuse has blown.

 

 

No power to the heat switch - check wiring for ‘opens.”

 

 

No power out of heat switch, follow troubleshooting steps to isolate the problem.

 

 

Call your distributor for additional help.

 

 

 

 